Outlier detection in high-density surface electromyographic signals.

Hamid R Marateb1, Monica Rojas-Martínez, Marjan Mansourian, Roberto Merletti, Miguel A Mañanas Villanueva.   

Abstract

Recently developed techniques allow the analysis of surface EMG in multiple locations over the skin surface (high-density surface electromyography, HDsEMG). The detected signal includes information from a greater proportion of the muscle of interest than conventional clinical EMG. However, recording with many electrodes simultaneously often implies bad-contacts, which introduce large power-line interference in the corresponding channels, and short-circuits that cause near-zero single differential signals when using gel. Such signals are called 'outliers' in data mining. In this work, outlier detection (focusing on bad contacts) is discussed for monopolar HDsEMG signals and a new method is proposed to identify 'bad' channels. The overall performance of this method was tested using the agreement rate against three experts' opinions. Three other outlier detection methods were used for comparison. The training and test sets for such methods were selected from HDsEMG signals recorded in Triceps and Biceps Brachii in the upper arm and Brachioradialis, Anconeus, and Pronator Teres in the forearm. The sensitivity and specificity of this algorithm were, respectively, 96.9 ± 6.2 and 96.4 ± 2.5 in percent in the test set (signals registered with twenty 2D electrode arrays corresponding to a total of 2322 channels), showing that this method is promising.

Entities:  

Mesh:

Year:  2011        PMID: 21698432     DOI: 10.1007/s11517-011-0790-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  11 in total

1.  The multivariate L1-median and associated data depth.

Authors:  Y Vardi; C H Zhang
Journal:  Proc Natl Acad Sci U S A       Date:  2000-02-15       Impact factor: 11.205

2.  Reducing power line interference in digitised electromyogram recordings by spectrum interpolation.

Authors:  D T Mewett; K J Reynolds; H Nazeran
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

3.  Robust outlier detection in high-density surface electromyographic signals.

Authors:  H R Marateb; M Rojas-Martinez; M A Mananas Villanueva; R Merletti
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

4.  On-line signal quality estimation of multichannel surface electromyograms.

Authors:  C Grönlund; K Roeleveld; A Holtermann; J S Karlsson
Journal:  Med Biol Eng Comput       Date:  2005-05       Impact factor: 2.602

5.  Strong-continuation, contrast-invariant inpainting with a third-order optimal PDE.

Authors:  Marcelo Bertalmío
Journal:  IEEE Trans Image Process       Date:  2006-07       Impact factor: 10.856

6.  G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences.

Authors:  Franz Faul; Edgar Erdfelder; Albert-Georg Lang; Axel Buchner
Journal:  Behav Res Methods       Date:  2007-05

7.  A frequency domain Hampel filter for blind rejection of sinusoidal interference from electromyograms.

Authors:  David P Allen
Journal:  J Neurosci Methods       Date:  2008-11-01       Impact factor: 2.390

8.  Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses.

Authors:  Franz Faul; Edgar Erdfelder; Axel Buchner; Albert-Georg Lang
Journal:  Behav Res Methods       Date:  2009-11

9.  Temporal changes in electrode impedance while recording the electrocardiogram with "dry" electrodes.

Authors:  L A Geddes; M E Valentinuzzi
Journal:  Ann Biomed Eng       Date:  1973-03       Impact factor: 3.934

10.  On surface EMG spectral characterization and its application to diagnostic classification.

Authors:  G F Inbar; A E Noujaim
Journal:  IEEE Trans Biomed Eng       Date:  1984-09       Impact factor: 4.538

View more
  6 in total

1.  Gesture recognition by instantaneous surface EMG images.

Authors:  Weidong Geng; Yu Du; Wenguang Jin; Wentao Wei; Yu Hu; Jiajun Li
Journal:  Sci Rep       Date:  2016-11-15       Impact factor: 4.379

2.  A real-time, practical sensor fault-tolerant module for robust EMG pattern recognition.

Authors:  Xiaorong Zhang; He Huang
Journal:  J Neuroeng Rehabil       Date:  2015-02-19       Impact factor: 4.262

3.  Detection of Multiple Innervation Zones from Multi-Channel Surface EMG Recordings with Low Signal-to-Noise Ratio Using Graph-Cut Segmentation.

Authors:  Hamid Reza Marateb; Morteza Farahi; Monica Rojas; Miguel Angel Mañanas; Dario Farina
Journal:  PLoS One       Date:  2016-12-15       Impact factor: 3.240

4.  High-density surface EMG maps from upper-arm and forearm muscles.

Authors:  Monica Rojas-Martínez; Miguel A Mañanas; Joan F Alonso
Journal:  J Neuroeng Rehabil       Date:  2012-12-10       Impact factor: 4.262

5.  Quantifying forearm muscle activity during wrist and finger movements by means of multi-channel electromyography.

Authors:  Marco Gazzoni; Nicolò Celadon; Davide Mastrapasqua; Marco Paleari; Valentina Margaria; Paolo Ariano
Journal:  PLoS One       Date:  2014-10-07       Impact factor: 3.240

6.  High-density surface electromyography signals during isometric contractions of elbow muscles of healthy humans.

Authors:  Mónica Rojas-Martínez; Leidy Yanet Serna; Mislav Jordanic; Hamid Reza Marateb; Roberto Merletti; Miguel Ángel Mañanas
Journal:  Sci Data       Date:  2020-11-16       Impact factor: 6.444

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.