Literature DB >> 21698397

Retropubic and transobturator slings: still useful or should all patients be treated with mini-slings?

Michael J Kennelly1, Erinn M Myers.   

Abstract

Traditional retropubic and transobturator midurethral slings are reliable, safe, and effective treatments for stress urinary incontinence. Unfortunately, they also are associated with rare but severe complications, such as bladder or bowel perforation, vascular injury, nerve damage, and/or groin muscle pain that can occur with the blind passage of trocars. To maintain efficacy and patient satisfaction while avoiding such complications, minimally invasive mini-slings have been developed. These smaller mini-slings can be placed through a single vaginal incision at the level of the midurethra without trocars. Mini-slings often are performed as an outpatient surgery, with minimal morbidity, pain, and quick patient recovery. With continued refinement and surgeon experience, mini-slings potentially may be performed safely in the office setting under local anesthesia while maintaining the efficacy of traditional slings. © Springer Science+Business Media, LLC 2011

Entities:  

Mesh:

Year:  2011        PMID: 21698397     DOI: 10.1007/s11934-011-0200-6

Source DB:  PubMed          Journal:  Curr Urol Rep        ISSN: 1527-2737            Impact factor:   3.092


  42 in total

1.  Transobturator TVT-O versus retropubic TVT: results of a multicenter randomized controlled trial at 24 months follow-up.

Authors:  Xavier Deffieux; Nagib Daher; Aslam Mansoor; Philippe Debodinance; Joël Muhlstein; Hervé Fernandez
Journal:  Int Urogynecol J       Date:  2010-06-16       Impact factor: 2.894

2.  Preliminary findings with the Solyx single-incision sling system in female stress urinary incontinence.

Authors:  Scott Serels; Michael Douso; Michael Duoso; Glori Short
Journal:  Int Urogynecol J       Date:  2009-12-19       Impact factor: 2.894

3.  Experience with TVT-SECUR sling for stress urinary incontinence: a 141-case analysis.

Authors:  Salil Khandwala; Chaandini Jayachandran; David Sengstock
Journal:  Int Urogynecol J       Date:  2010-02-26       Impact factor: 2.894

4.  Comparison of Efficacy and Satisfaction between the TVT-SECUR® and MONARC® Procedures for the Treatment of Female Stress Urinary Incontinence.

Authors:  Moo Youl Jeong; Su Jin Kim; Hyo Sin Kim; Jun Sung Koh; Joon Chul Kim
Journal:  Korean J Urol       Date:  2010-11-17

5.  Multicenter experience with the Monarc transobturator sling system to treat stress urinary incontinence.

Authors:  G W Davila; J D Johnson; S Serels
Journal:  Int Urogynecol J Pelvic Floor Dysfunct       Date:  2005-11-29

6.  Short-term outcomes with the Ajust™ system: a new single incision sling for the treatment of stress urinary incontinence.

Authors:  Michele Meschia; Pietro Barbacini; Roberto Baccichet; Arturo Buonaguidi; Marco Maffiolini; Luisa Ricci; Chiara Braghin; Valentina Brusati; Chiara Dell'Utri; Lorenzo Spreafico
Journal:  Int Urogynecol J       Date:  2010-08-27       Impact factor: 2.894

7.  A comparative study of outside-in and inside-out transobturator tape procedures for stress urinary incontinence.

Authors:  Hee-Dong Chae; So-Ra Kim; Gun-Ho Jeon; Dae-Yeon Kim; Sung-Hoon Kim; Jong-Hyeok Kim; Chung-Hoon Kim; Yong-Man Kim; Young-Tak Kim; Byung-Moon Kang; Joo-Hyun Nam
Journal:  Gynecol Obstet Invest       Date:  2010-07-17       Impact factor: 2.031

8.  Transobturator tape sling for female stress incontinence with polypropylene tape and outside-in procedure: prospective study with 1 year of minimal follow-up and review of transobturator tape sling.

Authors:  Philippe Grise; Stephane Droupy; Christian Saussine; Philippe Ballanger; Francois Monneins; Jean Francois Hermieu; Gerard Serment; Pierre Costa
Journal:  Urology       Date:  2006-10       Impact factor: 2.649

9.  Single-center retrospective study of the technique, safety, and 12-month efficacy of the MiniArc™ single-incision sling: a new minimally invasive procedure for treatment of female SUI.

Authors:  R D Moore; G K Mitchell; J R Miklos
Journal:  Surg Technol Int       Date:  2009-04

10.  Novel surgical technique for the treatment of female stress urinary incontinence: transobturator vaginal tape inside-out.

Authors:  Jean de Leval
Journal:  Eur Urol       Date:  2003-12       Impact factor: 20.096

View more
  2 in total

1.  Intraoperative Observation of the Degree and Pattern of Urine Leakage before Adjustment of the Mesh during a Transobturator Tape Procedure.

Authors:  Jae-Joon Park; Hyung Ho Lee; Young Sig Kim
Journal:  Chonnam Med J       Date:  2014-12-17

Review 2.  Meta-analysis of female stress urinary incontinence treatments with adjustable single-incision mini-slings and transobturator tension-free vaginal tape surgeries.

Authors:  Peng Zhang; Bohan Fan; Peng Zhang; Hu Han; Yue Xu; Biao Wang; Xiaodong Zhang
Journal:  BMC Urol       Date:  2015-07-07       Impact factor: 2.264

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.