Abstract

This paper presents characterization and initial imaging results of a 32 x 32 element two-dimensional capacitive micromachined ultrasonic transducer array. The devices are fabricated using a wafer bonding process in which both the insulation layer and the membrane are user-deposited silicon nitride. The transducers use a row-column addressing scheme to simplify the fabrication process and beamformer. By adjusting the number of rows and columns that are biased, the effective aperture of the transducer can be adjusted. This is significant because it permits imaging in the near-field of the transducer without the use of a lens. The effect on the transmit beam profile is demonstrated. The transducer has a center frequency of 5.9 MHz and a relative bandwidth of 110%. Images of horizontal and vertical wires are taken to demonstrate image resolution. A three-dimensional image of four pin heads is also demonstrated.

Entities:  

Mesh:

Year:  2011        PMID: 21693409     DOI: 10.1109/TUFFC.2011.1937

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  6 in total

1.  A Row-Column (RC) Addressed 2-D Capacitive Micromachined Ultrasonic Transducer (CMUT) Array on a Glass Substrate.

Authors:  Jean L Sanders; Ali Onder Biliroglu; Xun Wu; Oluwafemi J Adelegan; Feysel Yalcin Yamaner; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-02-25       Impact factor: 2.725

2.  Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

Authors:  Ibrahim Ben Daya; Albert I H Chen; Mohammad Javad Shafiee; Alexander Wong; John T W Yeow
Journal:  Sci Rep       Date:  2017-09-06       Impact factor: 4.379

Review 3.  Advances in Capacitive Micromachined Ultrasonic Transducers.

Authors:  Kevin Brenner; Arif Sanli Ergun; Kamyar Firouzi; Morten Fischer Rasmussen; Quintin Stedman; Butrus Pierre Khuri-Yakub
Journal:  Micromachines (Basel)       Date:  2019-02-23       Impact factor: 2.891

4.  Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model.

Authors:  Ibrahim Ben Daya; Albert I H Chen; Mohammad Javad Shafiee; Alexander Wong; John T W Yeow
Journal:  PLoS One       Date:  2015-12-11       Impact factor: 3.240

5.  The Design and Analysis of Split Row-Column Addressing Array for 2-D Transducer.

Authors:  Xu Li; Yanping Jia; Mingyue Ding; Ming Yuchi
Journal:  Sensors (Basel)       Date:  2016-09-27       Impact factor: 3.576

6.  Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves.

Authors:  Emmanuel Roux; François Varray; Lorena Petrusca; Christian Cachard; Piero Tortoli; Hervé Liebgott
Journal:  Sci Rep       Date:  2018-06-14       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.