Literature DB >> 21693399

Implementation of vibro-acoustography on a clinical ultrasound system.

Matthew W Urban1, Carl Chalek, Randall R Kinnick, Thomas M Kinter, Bruno Haider, James F Greenleaf, Kai E Thomenius, Mostafa Fatemi.   

Abstract

Vibro-acoustography is an ultrasound-based imaging modality that uses two ultrasound beams of slightly different frequencies to produce images based on the acoustic response caused by harmonic ultrasound radiation force excitation at the difference frequency between the two ultrasound frequencies. Vibro-acoustography has demonstrated feasibility and usefulness in imaging of breast and prostate tissue. However, previous studies have been performed either in controlled water tank settings or a prototype breast scanner equipped with a water tank. To make vibro-acoustography more accessible and relevant to clinical use, we report here on the implementation of vibro-acoustography on a General Electric Vivid 7 ultrasound scanner. In this paper, we will describe software and hardware modifications that were performed to make vibro- acoustography functional on this system. We will discuss aperture definition for the two ultrasound beams and beamforming using a linear-array transducer. Experimental results from beam measurements and phantom imaging studies will be shown. The implementation of vibro-acoustography provides a step toward clinical translation of this imaging modality for applications in various organs including breast, prostate, thyroid, kidney, and liver.

Entities:  

Mesh:

Year:  2011        PMID: 21693399      PMCID: PMC3138131          DOI: 10.1109/TUFFC.2011.1927

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  25 in total

1.  Vibro-acoustic tissue mammography.

Authors:  Mostafa Fatemi; Lester E Wold; Azra Alizad; James F Greenleaf
Journal:  IEEE Trans Med Imaging       Date:  2002-01       Impact factor: 10.048

2.  Vibro-acoustography: an imaging modality based on ultrasound-stimulated acoustic emission.

Authors:  M Fatemi; J F Greenleaf
Journal:  Proc Natl Acad Sci U S A       Date:  1999-06-08       Impact factor: 11.205

3.  Models and regulatory considerations for transient temperature rise during diagnostic ultrasound pulses.

Authors:  Bruce A Herman; Gerald R Harris
Journal:  Ultrasound Med Biol       Date:  2002-09       Impact factor: 2.998

4.  Improving the use of vibro-acoustography for brachytherapy metal seed imaging: a feasibility study.

Authors:  Farid G Mitri; Philippe Trompette; Jean-Yves Chapelon
Journal:  IEEE Trans Med Imaging       Date:  2004-01       Impact factor: 10.048

5.  Comparison of stress field forming methods for vibro-acoustography.

Authors:  Shigao Chen; Mostafa Fatemi; Randall Kinnick; James F Greenleaf
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-03       Impact factor: 2.725

6.  Thermal safety of vibro-acoustography using a confocal transducer.

Authors:  Shigao Chen; Wilkins Aquino; Azra Alizad; Matthew W Urban; Randall Kinnick; James F Greenleaf; Mostafa Fatemi
Journal:  Ultrasound Med Biol       Date:  2010-02       Impact factor: 2.998

7.  Stress field forming of sector array transducers for vibro-acoustography.

Authors:  Glauber T Silva; Shigao Chen; Alejandro C Frery; James F Greenleaf; Mostafa Fatemi
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-11       Impact factor: 2.725

8.  Multifrequency vibro-acoustography.

Authors:  Matthew W Urban; Glauber T Silva; Mostafa Fatemi; James F Greenleaf
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

9.  Ultrasound-stimulated vibro-acoustic spectrography.

Authors:  M Fatemi; J F Greenleaf
Journal:  Science       Date:  1998-04-03       Impact factor: 47.728

10.  Application of vibro-acoustography in prostate tissue imaging.

Authors:  Azra Alizad; Mohammad Mehrmohammadi; Farid G Mitri; Brian J Davis; Thomas J Sebo; Lance A Mynderse; Randall R Kinnick; James F Greenleaf; Mostafa Fatemi
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

View more
  17 in total

1.  Diagnosis of small partial-thickness rotator cuff tears using vibro-acoustography.

Authors:  Nobuyuki Yamamoto; Randall R Kinnick; Mostafa Fatemi; Takayuki Muraki; John W Sperling; Scott P Steinmann; Robert H Cofield; Eiji Itoi; Kai-Nan An
Journal:  J Med Ultrason (2001)       Date:  2014-06-26       Impact factor: 1.314

2.  A Review of Vibro-acoustography and its Applications in Medicine.

Authors:  Matthew W Urban; Azra Alizad; Wilkins Aquino; James F Greenleaf; Mostafa Fatemi
Journal:  Curr Med Imaging Rev       Date:  2011-11-01

3.  Application of vibro-acoustography in prostate tissue imaging.

Authors:  Azra Alizad; Mohammad Mehrmohammadi; Farid G Mitri; Brian J Davis; Thomas J Sebo; Lance A Mynderse; Randall R Kinnick; James F Greenleaf; Mostafa Fatemi
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

Review 4.  Acoustic radiation force elasticity imaging in diagnostic ultrasound.

Authors:  Joshua R Doherty; Gregg E Trahey; Kathryn R Nightingale; Mark L Palmeri
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-04       Impact factor: 2.725

5.  Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: a pilot ex vivo study.

Authors:  Mohammad Mehrmohammadi; Azra Alizad; Randall R Kinnick; Brian J Davis; Mostafa Fatemi
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  Vibro-acoustography beam formation with reconfigurable arrays.

Authors:  Hermes A S Kamimura; Matthew W Urban; Antonio A O Carneiro; Mostafa Fatemi; Azra Alizad
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-07       Impact factor: 2.725

7.  Preliminary in vivo breast vibro-acoustography results with a quasi-2-d array transducer: a step forward.

Authors:  Mohammad Mehrmohammadi; Robert T Fazzio; Dana H Whaley; Sandhya Pruthi; Randall R Kinnick; Mostafa Fatemi; Azra Alizad
Journal:  Ultrasound Med Biol       Date:  2014-12       Impact factor: 2.998

8.  Tissue mimicking materials for the detection of prostate cancer using shear wave elastography: a validation study.

Authors:  Rui Cao; Zhihong Huang; Tomy Varghese; Ghulam Nabi
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

Review 9.  Production of acoustic radiation force using ultrasound: methods and applications.

Authors:  Matthew W Urban
Journal:  Expert Rev Med Devices       Date:  2018-10-31       Impact factor: 3.166

10.  A beamforming study for implementation of vibro-acoustography with a 1.75-D array transducer.

Authors:  Matthew W Urban; Carl Chalek; Bruno Haider; Kai E Thomenius; Mostafa Fatemi; Azra Alizad
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.