Literature DB >> 21692957

Accuracy of circulating cathodic antigen tests for rapid mapping of Schistosoma mansoni and S. haematobium infections in Southern Sudan.

Ruth A Ashton1, Barclay T Stewart, Nora Petty, Mounir Lado, Timothy Finn, Simon Brooker, Jan H Kolaczinski.   

Abstract

OBJECTIVE: To evaluate the diagnostic accuracy of a circulating cathodic antigen (CCA) urine dipstick test for detecting Schistosoma mansoni and S. haematobium alongside an integrated rapid mapping survey in Southern Sudan. METHODS AND
RESULTS: A total of 373 children aged 5-16 years were included in the study. Of these 26.0% were infected with S. haematobium and 24.5% were infected with S. mansoni, as identified by urine filtration or single Kato-Katz thick smear, respectively. The CCA performed moderately in detecting S. mansoni, with sensitivity of 89.1% and specificity of 74.2%, and poorly in detecting S. haematobium infections, with a sensitivity of 36.8% and specificity of 78.9%. This may be a slight underestimate of true CCA accuracy, since only single stool and urine samples were examined by microscopy. The true 'gold standard' for comparison would have been the collection of multiple stool samples over consecutive days.
CONCLUSION: The poor CCA accuracy for diagnosis of urinary schistosomiasis means that this test is currently not suitable for rapid mapping of schistosomiasis in areas where both S. mansoni and S. haematobium may be endemic.
© 2011 Blackwell Publishing Ltd.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21692957     DOI: 10.1111/j.1365-3156.2011.02815.x

Source DB:  PubMed          Journal:  Trop Med Int Health        ISSN: 1360-2276            Impact factor:   2.622


  28 in total

Review 1.  Circulating antigen tests and urine reagent strips for diagnosis of active schistosomiasis in endemic areas.

Authors:  Eleanor A Ochodo; Gowri Gopalakrishna; Bea Spek; Johannes B Reitsma; Lisette van Lieshout; Katja Polman; Poppy Lamberton; Patrick M M Bossuyt; Mariska M G Leeflang
Journal:  Cochrane Database Syst Rev       Date:  2015-03-11

2.  Circulating cathodic antigen cassette test versus haematuria strip test in diagnosis of urinary schistosomiasis.

Authors:  Azza S El-Ghareeb; Ghada S Abd El Motaleb; Nevien Maher Waked; Nancy Osman Hany Kamel; Nagwa Shaban Aly
Journal:  J Parasit Dis       Date:  2015-02-14

3.  Diagnosis of Schistosoma mansoni without the stool: comparison of three diagnostic tests to detect Schistosoma [corrected] mansoni infection from filtered urine in Zambia.

Authors:  Nilanjan Lodh; James C L Mwansa; Mable M Mutengo; Clive J Shiff
Journal:  Am J Trop Med Hyg       Date:  2013-05-28       Impact factor: 2.345

4.  Schistosoma mansoni in a low-prevalence area in Brazil: the importance of additional methods for the diagnosis of hard-to-detect individual carriers by low-cost immunological assays.

Authors:  Rafaella Fortini Queiroz Grenfell; Watson Martins; Martin Enk; Aureo Almeida; Liliane Siqueira; Vanessa Silva-Moraes; Edward Oliveira; Nídia Francisca de Figueiredo Carneiro; Paulo Marcos Zech Coelho
Journal:  Mem Inst Oswaldo Cruz       Date:  2013-05       Impact factor: 2.743

Review 5.  Advances in the Diagnosis of Human Schistosomiasis.

Authors:  Kosala G A D Weerakoon; Geoffrey N Gobert; Pengfei Cai; Donald P McManus
Journal:  Clin Microbiol Rev       Date:  2015-10       Impact factor: 26.132

6.  The diagnosis and treatment of urogenital schistosomiasis in Italy in a retrospective cohort of immigrants from Sub-Saharan Africa.

Authors:  Marta Tilli; Federico Gobbi; Francesca Rinaldi; Jacopo Testa; Silvio Caligaris; Paola Magro; Dora Buonfrate; Monica Degani; Andrea Minervini; Marco Carini; Agostino Tuccio; Simone Sforza; Maurizio Gulletta; Francesco Castelli; Simone Agostini; Filippo Parretti; Joachim Richter; Piero Olliaro; Zeno Bisoffi; Alessandro Bartoloni; Lorenzo Zammarchi
Journal:  Infection       Date:  2019-01-21       Impact factor: 3.553

7.  Validity of urine-CCA cassette test and indirect haem-agglutination assay (IHA) in the detection of schistosomiasis-mansoni infection relative to microscopic examination.

Authors:  Enas A El Saftawy
Journal:  J Parasit Dis       Date:  2020-11-10

8.  The urine circulating cathodic antigen (CCA) dipstick: a valid substitute for microscopy for mapping and point-of-care diagnosis of intestinal schistosomiasis.

Authors:  José Carlos Sousa-Figueiredo; Martha Betson; Narcis B Kabatereine; J Russell Stothard
Journal:  PLoS Negl Trop Dis       Date:  2013-01-24

9.  Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

Authors:  Zeinab Demerdash; Salwa Mohamed; Mohamed Hendawy; Ibrahim Rabia; Mohy Attia; Zeinab Shaker; Tarek M Diab
Journal:  Korean J Parasitol       Date:  2013-02-18       Impact factor: 1.341

10.  New approaches with different types of circulating cathodic antigen for the diagnosis of patients with low Schistosoma mansoni load.

Authors:  Rafaella Grenfell; Donald A Harn; Smanla Tundup; Akram Da'dara; Liliane Siqueira; Paulo Marcos Zech Coelho
Journal:  PLoS Negl Trop Dis       Date:  2013-02-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.