| Literature DB >> 21692474 |
Lismery P Souza1, Francyelle Calegari, Aldo J G Zarbin, Luiz Humberto Marcolino-Junior, Marcio F Bergamini.
Abstract
A direct determination of gallic acid was achieved at a carbon paste electrode modified with carbon nanotubes under differential pulse voltammetry conditions. The values obtained for gallic acid were used to estimate the antioxidant properties of the wine sample based on gallic acid oxidation. The proposed method is based on the gallic acid oxidation process at a modified carbon paste electrode (MCPE) containing 30% (m/m) of carbon nanotubes monitored at 0.35 V versus Ag/AgCl (KCl 3 mol L(-1)). Using the optimized experimental conditions, the calibration curve for gallic acid was linear in the concentration range from 5.0 × 10(-7) to 1.5 × 10(-5) mol L(-1) with a detection limit of 3.0 × 10(-7) mol L(-1). The MCPE was successfully applied for the determination of the antioxidant capacity for red and white wine samples without interference of glucose and ascorbic acid, and the obtained results were compared with the standard spectrophotometric method.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21692474 DOI: 10.1021/jf2005589
Source DB: PubMed Journal: J Agric Food Chem ISSN: 0021-8561 Impact factor: 5.279