Literature DB >> 21692135

Thyroglobulin measurement in fine-needle aspiration biopsy of metastatic lymph nodes after rhTSH stimulation.

Carlo Cappelli1, Ilenia Pirola, Elvira De Martino, Elena Gandossi, Elena Cimino, Francesca Samoni, Barbara Agosti, Enrico Agabiti Rosei, Claudio Casella, Maurizio Castellano.   

Abstract

BACKGROUND: Thyroglobulin measurement in the washout of the needle used in fine-needle aspiration cytology (FNAC) has been proposed for the early detection of lymph node metastasis both in patients with or without serum thyroglobulin antibodies; however, up to now, there have been no reports that recombinant human thyrotropin (rhTSH) stimulation modifies thyroglobulin measurement in lymph node aspirates.
METHODS: We described, after rhTSH stimulation, the switching from undetectable to detectable levels of thyroglobulin in fine-needle aspiration fluid from a suspected metastatic lymph node in 2 patients.
RESULTS: We hypothesized that thyroglobulin levels in the lymph node increased after rhTSH stimulation. The excess thyroglobulin saturates all thyroglobulin antibody binding sites and becomes detectable, explaining why it was undetectable when TSH was suppressed.
CONCLUSION: On the basis of our experience, we suggest submitting to thyroglobulin measurement in the washout of the needle used in FNAC all patients with detectable serum thyroglobulin antibody after rhTSH stimulation.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21692135     DOI: 10.1002/hed.21796

Source DB:  PubMed          Journal:  Head Neck        ISSN: 1043-3074            Impact factor:   3.147


  4 in total

1.  A Study on Serum Antithyroglobulin Antibodies Interference in Thyroglobulin Measurement in Fine-Needle Aspiration for Diagnosing Lymph Node Metastasis in Postoperative Patients.

Authors:  Hyun Joo Shin; Hye Sun Lee; Eun-Kyung Kim; Hee Jung Moon; Ji Hye Lee; Jin Young Kwak
Journal:  PLoS One       Date:  2015-06-29       Impact factor: 3.240

2.  Any detectable thyroglobulin in lymph node biopsy washouts suggests local recurrence in differentiated thyroid cancer.

Authors:  Natalie Su-Jing Yap; Richard Maher; Diana Louise Learoyd
Journal:  Endocr Connect       Date:  2014-08-14       Impact factor: 3.335

3.  FER1L4/miR-372/E2F1 works as a ceRNA system to regulate the proliferation and cell cycle of glioma cells.

Authors:  Liang Xia; Dekang Nie; Guangtao Wang; Caixing Sun; Gao Chen
Journal:  J Cell Mol Med       Date:  2019-03-19       Impact factor: 5.310

4.  The value of combined application of ultrasound-guided fine needle aspiration cytology and thyroglobulin measurement for the diagnosis of cervical lymph node metastases from thyroid cancer.

Authors:  Jia-Hong Shi; Ying-Ying Xu; Qi-Zheng Pan; Guo-Qing Sui; Jian-Ping Zhou; Hui Wang
Journal:  Pak J Med Sci       Date:  2015 Sep-Oct       Impact factor: 1.088

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.