Fast radiofrequency flip angle calibration by Bloch-Siegert shift.

Laura I Sacolick1, Ling Sun, Mika W Vogel, W Thomas Dixon, Ileana Hancu.   

Abstract

In a recent work, we presented a novel method for B 1+ field mapping based on the Bloch-Siegert shift. Here, we apply this method to automated fast radiofrequency transmit gain calibration. Two off-resonance radiofrequency pulses were added to a slice-selective spin echo sequence. The off-resonance pulses induce a Bloch-Siegert phase shift in the acquired signal that is proportional to the square of the radiofrequency field magnitude B(1) (2) . The signal is further spatially localized by a readout gradient, and the signal-weighted average B(1) field is calculated. This calibration from starting system transmit gain to average flip angle is used to calculate the transmit gain setting needed to produce a desired imaging sequence flip angle. A robust implementation is demonstrated with a scan time of 3 s. The Bloch-Siegert-based calibration was used to predict the transmit gain for a 90° radiofrequency pulse and gave a flip angle of 88.6 ± 3.42° when tested in vivo in 32 volunteers.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21688314     DOI: 10.1002/mrm.22902

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Motion correction of multi-contrast images applied to T₁and T₂quantification in cardiac MRI.

Authors:  Anne Menini; Glenn S Slavin; Jeffrey A Stainsby; Pauline Ferry; Jacques Felblinger; Freddy Odille
Journal:  MAGMA       Date:  2015-02       Impact factor: 2.310

2.  Mapping electrical properties heterogeneity of tumor using boundary informed electrical properties tomography (BIEPT) at 7T.

Authors:  Yicun Wang; Qi Shao; Pierre-Francois Van de Moortele; Emilian Racila; Jiaen Liu; John Bischof; Bin He
Journal:  Magn Reson Med       Date:  2018-09-19       Impact factor: 4.668

3.  Multipathway multi-echo (MPME) imaging: all main MR parameters mapped based on a single 3D scan.

Authors:  Cheng-Chieh Cheng; Frank Preiswerk; W Scott Hoge; Tai-Hsin Kuo; Bruno Madore
Journal:  Magn Reson Med       Date:  2018-10-15       Impact factor: 4.668

4.  Improved Bloch-Siegert based B1 mapping by reducing off-resonance shift.

Authors:  Qi Duan; Peter van Gelderen; Jeff Duyn
Journal:  NMR Biomed       Date:  2013-01-28       Impact factor: 4.044

5.  Optimization and comparison of two practical dual-tuned birdcage configurations for quantitative assessment of articular cartilage with sodium magnetic resonance imaging.

Authors:  Gunthard Lykowsky; Flavio Carinci; Markus Düring; Daniel Weber; Peter M Jakob; Daniel Haddad
Journal:  Quant Imaging Med Surg       Date:  2015-12

6.  Robust 3D Bloch-Siegert based B 1 + mapping using multi-echo general linear modeling.

Authors:  Nadège Corbin; Julio Acosta-Cabronero; Shaihan J Malik; Martina F Callaghan
Journal:  Magn Reson Med       Date:  2019-07-18       Impact factor: 4.668

7.  Myelin water fraction mapping from multiple echo spin echoes and an independent B1 + map.

Authors:  Nima Mehdizadeh; Alan H Wilman
Journal:  Magn Reson Med       Date:  2022-05-16       Impact factor: 3.737

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.