Literature DB >> 21682427

Numerical simulation of ultrasonic wave propagation for the evaluation of dental implant biomechanical stability.

Vincent Mathieu1, Fani Anagnostou, Emmanuel Soffer, Guillaume Haiat.   

Abstract

Osseointegration of dental implants remains poorly understood. The objective of this numerical study is to understand the propagation phenomena of ultrasonic waves in prototypes cylindrically shaped implants and to investigate the sensitivity of their ultrasonic response to the surrounding bone biomechanical properties. The 10 MHz ultrasonic response of the implant was calculated using a finite difference numerical simulation tool and was compared to rf signals taken from a recent experimental study by Mathieu et al. [Ultrasound Med. Biol. 37, 262-270 (2011a)]. Reflection and mode conversion phenomena were analyzed to understand the origin of the different echoes and the importance of lateral wave propagation was evidenced. The sensitivity of the ultrasonic response of the implant to changes of (i) amount of bone in contact with the implant, (ii) cortical bone thickness, and (iii) surrounding bone material properties, was compared to the reproducibility of the measurements. The results show that, either a change of 1 mm of bone in contact with the implant, or 1.1 mm of cortical thickness or 12% of trabecular bone mass density should be detectable. This study paves the way for the investigation of the use of quantitative ultrasound techniques for the evaluation of bone-implant interface properties and implant stability.
© 2011 Acoustical Society of America

Mesh:

Substances:

Year:  2011        PMID: 21682427     DOI: 10.1121/1.3586788

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  6 in total

1.  Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications.

Authors:  Vaishnavi Bhaskar; Hsun-Liang Chan; Mark MacEachern; Oliver D Kripfgans
Journal:  Dentomaxillofac Radiol       Date:  2018-06-06       Impact factor: 2.419

2.  Ultrasonic Evaluation of the Bone-Implant Interface.

Authors:  Yoann Hériveaux; Vu-Hieu Nguyen; Guillaume Haïat
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

3.  Elastography of the bone-implant interface.

Authors:  Yoann Hériveaux; Vu-Hieu Nguyen; Didier Geiger; Guillaume Haïat
Journal:  Sci Rep       Date:  2019-10-02       Impact factor: 4.379

4.  Quantitative ultrasound assessment of the influence of roughness and healing time on osseointegration phenomena.

Authors:  M Fraulob; R Vayron; S Le Cann; B Lecuelle; Y Hériveaux; H Albini Lomami; C H Flouzat Lachaniette; G Haïat
Journal:  Sci Rep       Date:  2020-12-15       Impact factor: 4.379

5.  Plasmonic nanoantenna hydrophones.

Authors:  Ivan S Maksymov; Andrew D Greentree
Journal:  Sci Rep       Date:  2016-09-09       Impact factor: 4.379

6.  Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration.

Authors:  Romain Vayron; Vu-Hieu Nguyen; Benoît Lecuelle; Hugues Albini Lomami; Jean-Paul Meningaud; Romain Bosc; Guillaume Haiat
Journal:  Sensors (Basel)       Date:  2018-05-02       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.