Literature DB >> 21680946

Detection of pulmonary emboli with 99mTc-labeled anti-D-dimer (DI-80B3)Fab' fragments (ThromboView).

Timothy A Morris1, Michael Gerometta, Roger D Yusen, Richard H White, James D Douketis, Scott Kaatz, Richard C Smart, David Macfarlane, Jeffrey S Ginsberg.   

Abstract

RATIONALE: We report a new method to diagnose acute pulmonary embolism (PE) by single photon emission computerized tomography (SPECT) after administration of (99m)Tc-labeled anti-D-dimer (DI-80B3) monoclonal antibody Fab' fragments. This novel technique provides an additional approach to diagnosing PE in patients for whom other methods are nondiagnostic or contraindicated.
OBJECTIVES: We performed a prospective, multicenter study to investigate the sensitivity and specificity of (99m)Tc-DI-80B3/SPECT in patients with suspected acute PE.
METHODS: Subjects with a moderate to high clinical probability of PE or a positive D-dimer test underwent a PE-protocol contrast-enhanced multidetector thoracic computed tomography (CT) scan as well as (99m)Tc-DI-80B3/SPECT (0.5 mg (99m)Tc-DI-80B3 intravenously followed by a thoracic SPECT 2.5 h later). Separate and independent adjudication committees, blinded to clinical data and other test results, interpreted the (99m)Tc-DI-80B3/SPECT scans (PE detected as foci of abnormally increased (99m)Tc uptake) and the thoracic CT scans using Prospective Investigation of Pulmonary Embolism Diagnosis II criteria.
MEASUREMENTS AND MAIN RESULTS: Of the 52 patients who were enrolled and completed both tests, 42 had both evaluable SPECT scans and thoracic CT scans. Using the criterion standard (thoracic CT scan) there were 21 patients with PE and 21 without. (99m)Tc-DI-80B3/SPECT had a sensitivity of 76.2% (95% confidence interval, 52.8-91.8%) and a specificity of 90.5% (95% confidence interval, 69.8-98.8%). Treatment-related serious adverse events did not occur.
CONCLUSIONS: (99m)Tc-DI-80B3/SPECT was sensitive and specific for acute PE in subjects with moderate to high clinical probability of PE or a positive D-dimer test. (99m)Tc-DI-80B3/SPECT demonstrated an acceptable safety profile and avoids exposure to contrast.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21680946     DOI: 10.1164/rccm.201104-0624OC

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  11 in total

1.  Multisite Thrombus Imaging and Fibrin Content Estimation With a Single Whole-Body PET Scan in Rats.

Authors:  Francesco Blasi; Bruno L Oliveira; Tyson A Rietz; Nicholas J Rotile; Pratap C Naha; David P Cormode; David Izquierdo-Garcia; Ciprian Catana; Peter Caravan
Journal:  Arterioscler Thromb Vasc Biol       Date:  2015-08-13       Impact factor: 8.311

2.  Perfusion SPECT in patients with suspected pulmonary embolism.

Authors:  Marika Bajc; Massimo Miniati; Jonas Jögi; Paul D Stein
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-05-08       Impact factor: 9.236

3.  Radiation Dosimetry of the Fibrin-Binding Probe ⁶⁴Cu-FBP8 and Its Feasibility for PET Imaging of Deep Vein Thrombosis and Pulmonary Embolism in Rats.

Authors:  Francesco Blasi; Bruno L Oliveira; Tyson A Rietz; Nicholas J Rotile; Helen Day; Pratap C Naha; David P Cormode; David Izquierdo-Garcia; Ciprian Catana; Peter Caravan
Journal:  J Nucl Med       Date:  2015-05-14       Impact factor: 10.057

Review 4.  The role of molecular imaging in diagnosis of deep vein thrombosis.

Authors:  Sina Houshmand; Ali Salavati; Søren Hess; Mudalsha Ravina; Abass Alavi
Journal:  Am J Nucl Med Mol Imaging       Date:  2014-08-15

Review 5.  Fibrin-based biomaterials: modulation of macroscopic properties through rational design at the molecular level.

Authors:  Ashley C Brown; Thomas H Barker
Journal:  Acta Biomater       Date:  2013-09-19       Impact factor: 8.947

6.  Effect of Chelate Type and Radioisotope on the Imaging Efficacy of 4 Fibrin-Specific PET Probes.

Authors:  Francesco Blasi; Bruno L Oliveira; Tyson A Rietz; Nicholas J Rotile; Helen Day; Richard J Looby; Ilknur Ay; Peter Caravan
Journal:  J Nucl Med       Date:  2014-05-01       Impact factor: 10.057

7.  Discrete bimodal probes for thrombus imaging.

Authors:  Ritika Uppal; Kate L Ciesienski; Daniel B Chonde; Galen S Loving; Peter Caravan
Journal:  J Am Chem Soc       Date:  2012-06-20       Impact factor: 15.419

8.  Fibrin-targeted PET probes for the detection of thrombi.

Authors:  Katie L Ciesienski; Yan Yang; Ilknur Ay; Daniel B Chonde; Galen S Loving; Tyson A Rietz; Ciprian Catana; Peter Caravan
Journal:  Mol Pharm       Date:  2013-01-30       Impact factor: 4.939

Review 9.  State-of-the-Art Imaging for the Evaluation of Pulmonary Embolism.

Authors:  Leonid Roshkovan; Harold Litt
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-08-07

Review 10.  Peptide-based fibrin-targeting probes for thrombus imaging.

Authors:  Bruno L Oliveira; Peter Caravan
Journal:  Dalton Trans       Date:  2017-10-31       Impact factor: 4.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.