Literature DB >> 21679073

Transapical wire-assisted endovascular repair of thoracic aortic dissection.

Fabio Ramponi1, Michael P Vallely, Michael S Stephen, Paul G Bannon, Matthew S Bayfield, Geoffrey H White.   

Abstract

PURPOSE: To describe a technique for transapical wire-assisted endograft deployment under rapid ventricular pacing for a type B dissection involving the proximal left subclavian artery and extending to the aortic bifurcation. CASE REPORT: A 58-year-old man presented with a symptomatic thoracic aneurysm as a complication of a chronic type B dissection, with a short proximal neck in zone 1. After arch vessel debranching, the patient underwent endoluminal repair with deployment of a closed web, tapered Valiant thoracic endograft over a through-and-through wire from the left groin to the apex of the left ventricle, using rapid ventricular pacing to reduce cardiac output. The remaining dissected aorta was covered with a second Valiant endograft down to the distal third of the descending thoracic aorta and bare Z stents down to the aortic bifurcation to re-expand the true lumen. A freeflow Valiant endograft was deployed as a proximal extension to treat a proximal type I endoleak. The recovery was complicated by retrograde type A aortic dissection, considered secondary to the bare stent. The complication was repaired surgically; postoperative computed tomography after recovery was unremarkable.
CONCLUSION: Transapical wire-assisted deployment with rapid ventricular pacing is feasible and may provide improved stability for stenting within the aortic arch. The use of a stent-graft with a proximal bare stent is associated with a higher risk of retrograde extension of the dissection and warrants lifelong imaging follow-up.

Entities:  

Mesh:

Year:  2011        PMID: 21679073     DOI: 10.1583/10-3278.1

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  4 in total

1.  Think differently: trans-apical platform for TEVAR.

Authors:  Fabio Ramponi; Michael S Stephen; Michael K Wilson; Michael P Vallely
Journal:  Ann Cardiothorac Surg       Date:  2012-09

2.  [Endovascular treatment of thoracic aneurisms: indications, techniques and results].

Authors:  T Hofmockel; V Plodeck; R Grützmann; N Weiss; M Laniado; R-T Hoffmann
Journal:  Radiologe       Date:  2013-06       Impact factor: 0.635

3.  Externalized transapical guidewire technique after artificial aortic valve replacement during complete endovascular aortic arch repair.

Authors:  Tomasz Jędrzejczak; Paweł Rynio; Maciej Lewandowski; Arkadiusz Kazimierczak
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2020-03-27       Impact factor: 1.195

4.  The feasibility and safety of a through-and-through wire technique for central venous occlusion in dialysis patients.

Authors:  Yonghui Huang; Bing Chen; Guosheng Tan; Gang Cheng; Yi Zhang; Jiaping Li; Jianyong Yang
Journal:  BMC Cardiovasc Disord       Date:  2016-12-07       Impact factor: 2.298

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.