Literature DB >> 21676682

Transcatheter aortic valve implantation after previous mechanical mitral valve replacement: expanding indications?

Carsten J Beller1, Raffi Bekeredjian, Ulrike Krumsdorf, Rüdiger Leipold, Hugo A Katus, Matthias Karck, Wolfgang Rottbauer, Klaus Kallenbach.   

Abstract

BACKGROUND: Cardiac operation for severe aortic stenosis after previous mitral valve replacement is a surgical challenge in older patients with multiple morbidities. Transcatheter aortic valve implantation (TAVI) after previous mechanical mitral valve replacement has been considered a high-risk procedure, owing to possible interference with the mitral valve prosthesis.
METHODS: Since August 2008, 5 female high-risk patients with severe aortic stenosis and previous mitral valve replacement (mean ± SD age, 80 ± 5.1 years; logistic EuroSCORE, 39.3% ± 20.5%) underwent TAVI with a pericardial xenograft valve that was fixed with a stainless steel, balloon-expandable stent (Edwards Lifesciences SAPIEN). We used a transapical approach in 4 patients and a transfemoral approach in 1 patient. Transesophageal echocardiography and multidetector computed tomography were used for preoperative planning and assessment of operation feasibility. The mean distance between the aortic annulus and the mitral valve prosthesis was 10 ± 1 mm (range, 9-11 mm).
RESULTS: TAVI was performed successfully in all 5 patients. There was no direct or functional interference with the mechanical mitral valve prostheses. Echocardiography revealed good valve function with no more than mild paravalvular incompetence early in the postoperative period and during routine follow-up. There were no neurologic events. After an initially uneventful course with good aortic valve function at the most recent echocardiography evaluation, however, 2 of the patients died from fulminant pneumonia on postoperative days 4 and 48.
CONCLUSION: TAVI is technically feasible in high-risk patients after previous mechanical mitral valve replacement; however, careful patient selection is mandatory with respect to preoperative clinical status and anatomic dimensions regarding the distance between aortic annulus and mitral valve prosthesis.

Entities:  

Mesh:

Year:  2011        PMID: 21676682     DOI: 10.1532/HSF98.20101148

Source DB:  PubMed          Journal:  Heart Surg Forum        ISSN: 1098-3511            Impact factor:   0.676


  8 in total

1.  Transcatheter aortic valve implantation after previous mechanical mitral valve replacement in a patient with coexistent rheumatic aortic stenosis and regurgitation.

Authors:  Yuehuan Li; Haibo Zhang; Yujie Zhou; Xu Meng
Journal:  Cardiovasc Diagn Ther       Date:  2019-10

2.  The groin first approach for transcatheter aortic valve implantation: are we pushing the limits for transapical implantation?

Authors:  Carsten J Beller; Bastian Schmack; Philipp Seppelt; Rawa Arif; Raffi Bekeredjian; Ulrike Krumsdorf; Hugo A Katus; Matthias Karck; Klaus Kallenbach
Journal:  Clin Res Cardiol       Date:  2012-08-05       Impact factor: 5.460

3.  Early experiences and in-hospital results with a novel off-pump apico-aortic conduit.

Authors:  Oliver Reuthebuch; Jens Fassl; John Brown; Martin Grapow; Friedrich Eckstein
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-01-09

4.  Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation.

Authors:  Markus Schlömicher; Peter Lukas Haldenwang; Vadim Moustafine; Britta Wolf; Peter Zahn; Matthias Bechtel; Justus Thomas Strauch
Journal:  Thorac Cardiovasc Surg Rep       Date:  2016-04-04

5.  Sutureless aortic valve and mitral valve repair in redo cases - really an off-label approach?

Authors:  Júlia Čanádyová; Aleš Mokráček; Vojtěch Kurfirst
Journal:  Kardiochir Torakochirurgia Pol       Date:  2016-12-30

6.  Transcatheter aortic valve replacement in patients with previous mitral valve replacement. A systematic study.

Authors:  Zbigniew Chmielak; Maciej Dąbrowski; Paweł Tyczyński; Krzysztof Kukuła; Ilona Michałowska; Emilia Szudejko; Jarosław Skowroński; Mariusz Kuśmierczyk; Adam Witkowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2020-06-23       Impact factor: 1.426

7.  Transapical Implantation of a 2nd-Generation JenaValve Device in Patient with Extremely High Surgical Risk.

Authors:  Juan Mieres; Marcelo Menéndez; Carlos Fernández-Pereira; Miguel Rubio; Alfredo E Rodríguez
Journal:  Case Rep Cardiol       Date:  2015-08-04

8.  Transapical aortic valve implantation in patients with pre-existing mitral valve prostheses: a case report.

Authors:  Kristina Wachter; Samir Ahad; Christian J Rustenbach; Ulrich F W Franke; Hardy Baumbach
Journal:  J Cardiothorac Surg       Date:  2016-08-08       Impact factor: 1.637

  8 in total