Preoperative fluoroscopic imaging reduces variability of acetabular component positioning.

Yoshiki Nishikubo1, Mikihiro Fujioka, Keiichiro Ueshima, Masazumi Saito, Toshikazu Kubo.   

Abstract

We evaluated the preoperative errors in the pelvic tilt of 249 hips before total hip arthroplasty using fluoroscopic imaging while the patients were in the lateral decubitus position. The mean absolute value errors of the pelvic tilt were 2.94° (SD, 2.92°), 2.49° (SD, 2.68°), and 5.92° (SD, 5.20°) in the coronal, transverse, and sagittal planes, respectively. Such preoperative errors in the pelvic tilt contribute to malpositioning of the acetabular component, as is frequently observed on postoperative radiographs. We reduced the incidence of malpositioning by correcting the errors in the pelvic tilt through repositioning of the operating table using fluoroscopic imaging before surgery. The new technique using fluoroscopic imaging described in this article can be performed within a short time without a navigation system.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21676577     DOI: 10.1016/j.arth.2011.05.011

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  A novel non-invasive mechanical technique of cup and stem placement and leg length adjustment in total hip arthroplasty for dysplastic hips.

Authors:  Takashi Murayama; Hideo Ohnishi; Toshiharu Mori; Yuichi Okazaki; Kenji Sujita; Akinori Sakai
Journal:  Int Orthop       Date:  2014-12-09       Impact factor: 3.075

2.  Does fluoroscopy with anterior hip arthroplasty decrease acetabular cup variability compared with a nonguided posterior approach?

Authors:  Parthiv A Rathod; Sean Bhalla; Ajit J Deshmukh; Jose A Rodriguez
Journal:  Clin Orthop Relat Res       Date:  2014-02-19       Impact factor: 4.176

3.  Surgeons changing the approach for total hip arthroplasty from posterior to direct anterior with fluoroscopy should consider potential excessive cup anteversion and flexion implantation of the stem in their early experience.

Authors:  Hideo Kobayashi; Yasuhiro Homma; Tomonori Baba; Hironori Ochi; Mikio Matsumoto; Takahito Yuasa; Kazuo Kaneko
Journal:  Int Orthop       Date:  2015-12-04       Impact factor: 3.075

4.  Cup Alignment Change after Screw Fixation in Total Hip Arthroplasty.

Authors:  Yingyong Suksathien; Urawit Piyapromdee; Thanut Tippimanchai
Journal:  Indian J Orthop       Date:  2019 Sep-Oct       Impact factor: 1.251

5.  Pelvic Tilt Reduces the Accuracy of Acetabular Component Placement When Using a Portable Navigation System: An In Vitro Study.

Authors:  Hiroshi Asai; Yasuhiko Takegami; Taisuke Seki; Naoki Ishiguro
Journal:  Arthroplast Today       Date:  2021-02-01

Review 6.  Cup placement in primary total hip arthroplasty: how to get it right without navigation or robotics.

Authors:  Geert Meermans; George Grammatopoulos; Moritz Innmann; David Beverland
Journal:  EFORT Open Rev       Date:  2022-05-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.