Literature DB >> 21674453

Ultrasound-guided puncture of the femoral artery for total percutaneous aortic aneurysm repair.

Levent Oğuzkurt1, Kamil Gürel, Evren Eker, Serkan Gür, Uğur Özkan, Öner Gülcan.   

Abstract

PURPOSE: The purpose of this study was to evaluate the outcomes of ultrasound-guided femoral artery access for total percutaneous endovascular repair of abdominal and thoracic aortic aneurysms.
MATERIALS AND METHODS: Total percutaneous aneurysm repair of the abdominal and thoracic aorta was performed in 52 consecutive patients (46 males, 6 females; mean age, 64.6±16 years; age range, 24-93 years) in a total of 85 access arteries. Of the aortic aneurysms repaired, 33 were abdominal, and 19 were thoracic. Ultrasound- guided puncture of the access artery was performed in all patients. The access artery was closed with a Prostar XL device at the end of the procedure.
RESULTS: The outer diameter of the vascular sheaths or the stent graft system ranged from 14 F to 27 F. All but one patient achieved successful closure of the arterial puncture with the closure device. One patient required surgical cutdown because of device failure. Two patients required long-duration manual compression. Technical success was achieved in 49 patients (94%). Forty-five patients (87%) were discharged on the first postoperative day. There were no complications of the access arteries one day or one month postoperatively, as determined by ultrasonography and computed tomography examinations, respectively. The mean diameters of the access arteries prior to and one month after the procedure were unchanged, as demonstrated by computed tomography.
CONCLUSION: Ultrasound-guided puncture of the common femoral artery for percutaneous closure of the access site has a high technical success rate and a very low complication rate. The addition of ultrasound guidance decreases the difficulty of the procedure and helps to avoid some of its complications.

Entities:  

Mesh:

Year:  2011        PMID: 21674453     DOI: 10.4261/1305-3825.DIR.4061-10.1

Source DB:  PubMed          Journal:  Diagn Interv Radiol        ISSN: 1305-3825            Impact factor:   2.630


  5 in total

1.  Ultrasound-guided percutaneous endovascular aneurysm repair success is predicted by access vessel diameter.

Authors:  Rodney P Bensley; Rob Hurks; Zhen Huang; Frank Pomposelli; Allen Hamdan; Mark Wyers; Elliot Chaikof; Marc L Schermerhorn
Journal:  J Vasc Surg       Date:  2012-02-22       Impact factor: 4.268

2.  A single-centre experience of 200 consecutive unselected patients in percutaneous EVAR.

Authors:  Sergio Petronelli; Maria Teresa Zurlo; Silvia Giambersio; Lucia Danieli; Mariaelena Occhipinti
Journal:  Radiol Med       Date:  2014-04-04       Impact factor: 3.469

3.  Endovascular repair of thoracic and abdominal aortic ruptures: a single-center experience.

Authors:  Filiz İslim; Aysun Erbahçeci Salık; Koray Güven; Vedat Bakuy; Zafer Çukurova
Journal:  Diagn Interv Radiol       Date:  2014 May-Jun       Impact factor: 2.630

4.  Total percutaneous femoral vessels cannulation for minimally invasive mitral valve surgery.

Authors:  Matteo Pozzi; Roland Henaine; Daniel Grinberg; Jacques Robin; Christine Saroul; Bertrand Delannoy; Olivier Desebbe; Jean-François Obadia
Journal:  Ann Cardiothorac Surg       Date:  2013-11

5.  Comparing and Correlating Outcomes between Open and Percutaneous Access in Endovascular Aneurysm Repair in Aortic Aneurysms Using a Retrospective Cohort Study Design.

Authors:  Peter DeVito; Ali Kimyaghalam; Sameh Shoukry; Robert DeVito; John Williams; Eashaa Kumar; Eugene Vitvitsky
Journal:  Int J Vasc Med       Date:  2020-11-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.