Literature DB >> 21674313

Starr-Edwards valves at the aortic and mitral positions implanted for 39 years.

Shun-ichi Misawa1, Kei Aizawa, Yuichiro Kaminishi, Arata Muraoka, Yoshio Misawa.   

Abstract

Cloth-covered Starr-Edwards caged ball valves implanted in the aortic and mitral valve positions for 39 years were extracted. Both showed valve dysfunction resulting from pannus overgrowth. The metal cages of the Starr-Edwards valves were covered with worn cloth. This case indicates the extended durability of Starr-Edwards valves and the importance of the design and materials of prosthetic heart valves to avoid pannus overgrowth and prosthetic valve abrasion.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21674313     DOI: 10.1007/s11748-010-0715-7

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  6 in total

1.  Late re-operation for aortic and mitral Starr-Edwards ball valve prostheses.

Authors:  Shigeaki Aoyagi; Shuji Fukunaga; Koichi Arinaga; Yoshinori Yokokura; Hiroko Yokokura; Noriko Egawa
Journal:  Asian Cardiovasc Thorac Ann       Date:  2006-12

2.  Extended (31 years) durability of a Starr-Edwards prosthesis in mitral position.

Authors:  Vincenzo Tarzia; Tomaso Bottio; Luca Testolin; Gino Gerosa
Journal:  Interact Cardiovasc Thorac Surg       Date:  2007-05-02

3.  Pannus resection through the tilting disc prosthesis: successful treatment preserving the prosthesis.

Authors:  Y Misawa; K Fuse; M Kato
Journal:  Artif Organs       Date:  1997-12       Impact factor: 3.094

4.  Long-term results of the cloth-covered Starr-Edwards ball valve.

Authors:  Motomi Shiono; Yukiyasu Sezai; Akira Sezai; Mitsumasa Hata; Mitsuru Iida; Nanao Negishi
Journal:  Ann Thorac Surg       Date:  2005-07       Impact factor: 4.330

5.  Prophylactic reoperation after mitral valve replacement with the Starr-Edwards ball valve: a report of four cases.

Authors:  Akira Sezai; Mitsumasa Hata; Tetsuya Niino; Masataka Yoda; Shinji Wakui; Tomofumi Umeda; Kazuma Shimura; Nobuyuki Furukawa; Kohtaroh Tokai; Yuji Kasamaki; Kazutomo Minami
Journal:  Ann Thorac Cardiovasc Surg       Date:  2007-10       Impact factor: 1.520

6.  When and how does nonstructural mechanical prosthetic heart valve dysfunction occur?

Authors:  Yoshio Misawa; Tsutomu Saito; Hiroaki Konishi; Shin-ichi Oki; Yuichiro Kaminishi; Hideki Takahashi; Kei Aizawa; Osamu Kamisawa; Morito Kato; Katsuo Fuse
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2003-08
  6 in total
  2 in total

Review 1.  Valve-related complications after mechanical heart valve implantation.

Authors:  Yoshio Misawa
Journal:  Surg Today       Date:  2014-12-18       Impact factor: 2.549

2.  Unique nonstructural dysfunction of the omnicarbon valve: case report.

Authors:  Soki Kurumisawa; Yuichiro Kaminishi; Arata Muraoka; Yoshio Misawa
Journal:  J Cardiothorac Surg       Date:  2016-03-29       Impact factor: 1.637

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.