Literature DB >> 21671711

Analysis of maxillary arch force/couple systems for a simulated high canine malocclusion: Part 2. Elastic ligation.

Jonathan Fok1, Roger W Toogood, Hisham Badawi, Jason P Carey, Paul W Major.   

Abstract

OBJECTIVE: To better understand the mechanics of bracket/archwire interaction through analysis of force and couple distribution along the maxillary arch using elastic ligation and to compare these results with passive ligation.
MATERIALS AND METHODS: An orthodontic simulator was used to study a high canine malocclusion. Force and couple distributions produced by elastic ligation and round wire were measured. Forces and couples were referenced to the center of resistance of each tooth. Tests were repeated for 12 bracket sets with 12 wires per set. Data were compared with those derived from similar tests for passive ligation.
RESULTS: Propagation of the force/couple systems around the arch using elastic ligation was extensive. Elastic ligation produced significantly more resistance to sliding, contributing to higher forces and couples at the center of resistance than were observed for passive ligation.
CONCLUSIONS: The results of this study suggest some potential mechanical advantages of passive over elastic ligation. In particular, limited propagation around the arch in passive ligation reduces the occurrence of unwanted force/couple systems compared with elastic ligation. These advantages may not transfer to a clinical setting because of the conditions of the tests; additional testing would be required to determine whether these advantages can be generalized.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21671711      PMCID: PMC8903858          DOI: 10.2319/012011-41.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  8 in total

1.  An ex-vivo investigation into the effect of bracket displacement on the resistance to sliding.

Authors:  D O'Reilly; P A Dowling; L Lagerstrom; M L Swartz
Journal:  Br J Orthod       Date:  1999-09

2.  Forces released by nonconventional bracket or ligature systems during alignment of buccally displaced teeth.

Authors:  Lorenzo Franchi; Tiziano Baccetti; Matteo Camporesi; Veronica Giuntini
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-09       Impact factor: 2.650

3.  Forces exerted by conventional and self-ligating brackets during simulated first- and second-order corrections.

Authors:  Nikolaos Pandis; Theodore Eliades; Samira Partowi; Christoph Bourauel
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-05       Impact factor: 2.650

4.  Three-dimensional orthodontic force measurements.

Authors:  Hisham M Badawi; Roger W Toogood; Jason P R Carey; Giseon Heo; Paul W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-10       Impact factor: 2.650

5.  Forces and moments on posterior teeth generated by incisor intrusion biomechanics.

Authors:  I Sifakakis; N Pandis; M Makou; T Eliades; C Bourauel
Journal:  Orthod Craniofac Res       Date:  2009-11       Impact factor: 1.826

6.  The leveling effectiveness of self-ligating and conventional brackets for complex tooth malalignments.

Authors:  Magali Fansa; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2009-08-02       Impact factor: 1.938

7.  Quantification of three-dimensional orthodontic force systems of T-loop archwires.

Authors:  Jie Chen; Serkis C Isikbay; Edward J Brizendine
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

8.  Analysis of maxillary arch force/couple systems for a simulated high canine malocclusion: Part 1. Passive ligation.

Authors:  Jonathan Fok; Roger W Toogood; Hisham Badawi; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2011-07-20       Impact factor: 2.079

  8 in total
  3 in total

1.  First order couples induced by nickel-titanium archwires featuring an electrochemically refined surface during simulated rotation of teeth.

Authors:  Leif Johannessen; Ludger Keilig; Susanne Reimann; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

2.  Analysis of maxillary arch force/couple systems for a simulated high canine malocclusion: Part 1. Passive ligation.

Authors:  Jonathan Fok; Roger W Toogood; Hisham Badawi; Jason P Carey; Paul W Major
Journal:  Angle Orthod       Date:  2011-07-20       Impact factor: 2.079

3.  Effect of ligation method on maxillary arch force/moment systems for a simulated lingual incisor malalignment.

Authors:  Surbhi Seru; Dan L Romanyk; Roger W Toogood; Jason P Carey; Paul W Major
Journal:  Open Biomed Eng J       Date:  2014-10-30
  3 in total