Literature DB >> 21667980

Hydrophilic pyrazine dyes as exogenous fluorescent tracer agents for real-time point-of-care measurement of glomerular filtration rate.

Raghavan Rajagopalan1, William L Neumann, Amruta R Poreddy, Richard M Fitch, John N Freskos, Bethel Asmelash, Kimberly R Gaston, Karen P Galen, Jeng-Jong Shieh, Richard B Dorshow.   

Abstract

Various hydrophilic pyrazine-bis(carboxamides) derived from 3,5-diamino-pyrazine-2,5-dicarboxylic acid bearing neutral and anionic groups were prepared and evaluated for use as fluorescent glomerular filtration rate (GFR) tracer agents. Among these, the dianionic d-serine pyrazine derivatives 2d and 2j, and the neutral dihydroxypropyl 2h, exhibited favorable physicochemical and clearance properties. In vitro studies show that 2d, 2h, and 2j have low plasma protein binding, a necessary condition for renal excretion. In vivo animal model results show that these three compounds exhibit a plasma clearance equivalent to iothalamate (a commonly considered gold standard GFR agent). In addition, these compounds have a higher urine recovery compared to iothalamate. Finally, the plasma clearance of 2d, 2h, and 2j remained unchanged upon blockage of the tubular secretion pathway with probenecid, a necessary condition for establishment of clearance via glomerular filtration only. Hence, 2d, 2h, and 2j are promising candidates for translation to the clinic as exogenous fluorescent tracer agents in real-time point-of-care monitoring of GFR.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21667980     DOI: 10.1021/jm200257k

Source DB:  PubMed          Journal:  J Med Chem        ISSN: 0022-2623            Impact factor:   7.446


  10 in total

Review 1.  Quantifying Glomerular Filtration Rates in Acute Kidney Injury: A Requirement for Translational Success.

Authors:  Bruce A Molitoris; Erinn S Reilly
Journal:  Semin Nephrol       Date:  2016-01       Impact factor: 5.299

2.  Water-soluble, deep-red fluorescent squaraine rotaxanes.

Authors:  Erin L Cole; Easwaran Arunkumar; Shuzhang Xiao; Bryan A Smith; Bradley D Smith
Journal:  Org Biomol Chem       Date:  2011-12-08       Impact factor: 3.876

Review 3.  Rethinking CKD Evaluation: Should We Be Quantifying Basal or Stimulated GFR to Maximize Precision and Sensitivity?

Authors:  Bruce A Molitoris
Journal:  Am J Kidney Dis       Date:  2017-02-20       Impact factor: 8.860

4.  Metal-free [3 + 2 + 1]/[2 + 2 + 1] biscyclization: stereospecific construction with concomitant functionalization of indolizin-5(1H)-one.

Authors:  Tuan-Jie Li; Zhong-Qiu Liu; Hong-Mei Yin; Chang-Sheng Yao; Bo Jiang; Xiang-Shan Wang; Shu-Jiang Tu; Xiu-Ling Li; Guigen Li
Journal:  J Org Chem       Date:  2013-11-07       Impact factor: 4.354

5.  Reliability of transcutaneous measurement of renal function in various strains of conscious mice.

Authors:  Daniel Schock-Kusch; Stefania Geraci; Esther Ermeling; Yury Shulhevich; Carsten Sticht; Juergen Hesser; Dzmitry Stsepankou; Sabine Neudecker; Johannes Pill; Roland Schmitt; Anette Melk
Journal:  PLoS One       Date:  2013-08-19       Impact factor: 3.240

Review 6.  Light-Emitting Agents for Noninvasive Assessment of Kidney Function.

Authors:  Jiaguo Huang; Norbert Gretz
Journal:  ChemistryOpen       Date:  2017-07-20       Impact factor: 2.911

7.  Zwitterionic near infrared fluorescent agents for noninvasive real-time transcutaneous assessment of kidney function.

Authors:  Jiaguo Huang; Stefanie Weinfurter; Cristina Daniele; Rossana Perciaccante; Rodeghiero Federica; Leopoldo Della Ciana; Johannes Pill; Norbert Gretz
Journal:  Chem Sci       Date:  2017-01-11       Impact factor: 9.825

Review 8.  Renal recovery after acute kidney injury.

Authors:  L G Forni; M Darmon; M Ostermann; H M Oudemans-van Straaten; V Pettilä; J R Prowle; M Schetz; M Joannidis
Journal:  Intensive Care Med       Date:  2017-05-02       Impact factor: 17.440

9.  Transdermal fluorescence detection of a dual fluorophore system for noninvasive point-of-care gastrointestinal permeability measurement.

Authors:  Richard B Dorshow; J R Johnson; Martin P Debreczeny; I Rochelle Riley; Jeng-Jong Shieh; Thomas E Rogers; Carla Hall-Moore; Nurmohammad Shaikh; L Colleen Rouggly-Nickless; Phillip I Tarr
Journal:  Biomed Opt Express       Date:  2019-09-13       Impact factor: 3.732

10.  Simultaneous measurement of kidney function by dynamic contrast enhanced MRI and FITC-sinistrin clearance in rats at 3 tesla: initial results.

Authors:  Frank G Zöllner; Daniel Schock-Kusch; Sandra Bäcker; Sabine Neudecker; Norbert Gretz; Lothar R Schad
Journal:  PLoS One       Date:  2013-11-18       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.