Literature DB >> 21667897

Preliminary clinical and radiographic results of large ceramic heads on highly cross-linked polyethylene.

Morteza Meftah1, Prouskeh Bruce Ebrahimpour, Chuan He, Amar S Ranawat, Chitranjan S Ranawat.   

Abstract

Data are limited regarding large ceramic femoral heads with highly cross-linked polyethylene. We hypothesized that large ceramic head articulation with highly cross-linked polyethylene is safe with a low wear rate, comparable to metal-on-highly cross-linked polyethylene.The study group comprised 63 patients (72 hips) who had undergone total hip replacement (THR) with ceramic-on-highly cross-linked polyethylene between April 2006 and March 2007 with a minimum 2-year follow-up. Postoperative Western Ontario and Mc-Master Universities Arthritis Index (WOMAC) and Hospital for Special Surgery (HSS) scores were used for clinical assessment. Six-week and 2-year radiographs were analyzed by 2 independent observers using Roman 1.70 software. Twenty-six patients (29 hips) had 32-mm and 37 patients (43 hips) had 36-mm Biolox delta ceramic femoral heads (Ceramtec, Plochingen, Germany). Mean patient age was 60.9 ± 8.9 years, and mean follow-up was 2.9 ± 0.5 years. Mean postoperative WOMAC and HSS hip scores were 30.4 and 36.6, respectively. Mean wear at 1 and 2 years postoperatively was 0.06 ± 0.28 and 0.006 ± 0.12 mm/yr for all hips, respectively. Mean wear at 1 and 2 years postoperatively for the 32-mm femoral head was 0.063 ± 0.278 and 0.007 ± 0.126 mm/yr, respectively, and for the 36-mm femoral head was 0.057 ± 0.292 and 0.006 ± 0.118 mm/yr, respectively. No patient had any clinical complications, such as reoperation, infection, fractures, or radiographic evidence of osteolysis or loosening. The early results of THR with large ceramic heads demonstrate high safety and efficacy. Our data with 2-year follow-up show low wear rates, similar to published data for metal-on-highly cross-linked polyethylene. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21667897     DOI: 10.3928/01477447-20110427-08

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  6 in total

1.  No difference in gait recovery after THA with different head diameters: a prospective randomized study.

Authors:  Luigi Zagra; Federica Anasetti; Luca Bianchi; Vittorio Licari; Roberto Giacometti Ceroni
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

2.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

3.  Ceramic Bearings with Titanium Adapter Sleeves Implanted During Revision Hip Arthroplasty Show Minimal Fretting or Corrosion: a Retrieval Analysis.

Authors:  Chelsea N Koch; Mark Figgie; Mark P Figgie; Marcella E Elpers; Timothy M Wright; Douglas E Padgett
Journal:  HSS J       Date:  2017-06-22

4.  Bearing surfaces in primary total hip arthroplasty.

Authors:  Luigi Zagra; Enrico Gallazzi
Journal:  EFORT Open Rev       Date:  2018-05-21

5.  Modeling of the Influence of Input AM Parameters on Dimensional Error and Form Errors in PLA Parts Printed with FFF Technology.

Authors:  Carmelo J Luis-Pérez; Irene Buj-Corral; Xavier Sánchez-Casas
Journal:  Polymers (Basel)       Date:  2021-11-27       Impact factor: 4.329

6.  Long-term durability of alumina ceramic heads in THA.

Authors:  Nicholas A Beckmann; Tobias Gotterbarm; Moritz M Innmann; Christian Merle; Thomas Bruckner; J Philippe Kretzer; Marcus R Streit
Journal:  BMC Musculoskelet Disord       Date:  2015-09-12       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.