Biaxial flexural strength of CAD/CAM ceramics.

L Buso1, O B Oliveira-Júnior, F Hiroshi Fujiy, G H Leão Lombardo, H Ramalho Sarmento, F Campos, R O Assunção Souza.   

Abstract

AIM: Aim of the study was to evaluate the biaxial flexural strength of ceramics processed using the Cerec inLab system. The hypothesis was that the flexural strength would be influenced by the type of ceramic.
METHODS: Ten samples (ISO 6872) of each ceramic (N.=50/n.=10) were made using Cerec inLab (software Cerec 3D) (Ø:15 mm, thickness: 1.2 mm). Three silica-based ceramics (Vita Mark II [VM], ProCad [PC] and e-max CAD ECAD]) and two yttria-stabilized tetragonal-zirconia-polycrystalline ceramics (Y-TZP) (e-max ZirCad [ZrCAD] and Vita In-Ceram 2000 YZ Cubes [VYZ]) were tested. The samples were finished with wet silicone carbide papers up to 1 200-grit and polished in a polishing machine with diamond paste (3 µm). The samples were then submitted to biaxial flexural strength testing in a universal testing machine (EMIC), 1 mm/min. The data (MPa) were analyzed using the Kruskal-Wallis and Dunn (5%) tests. Scanning electronic microscopy (SEM) was performed on a representative sample from each group.
RESULTS: The values (median, mean±sd) obtained for the experimental groups were: VM (101.7, 102.1±13.65 MPa), PC (165.2, 160±34.7 MPa), ECAD (437.2, 416.1±50.1 MPa), ZrCAD (804.2, 800.8±64.47 MPa) and VYZ (792.7, 807±100.7 MPa). The type of ceramic influenced the flexural strength values (P=0.0001). The ceramics ECADa, e-max ZrCADa and VYZa presented similar flexural strength values which were significantly higher than the other groups (PCb and VM IIb), which were similar statistically between them (Dunn's test). The hypothesis was accepted.
CONCLUSION: The polycrystalline ceramics (Y-TZP) should be material chosen for make FPDs because of their higher flexural strength values.

Entities:  

Mesh:

Year:  2011        PMID: 21666567

Source DB:  PubMed          Journal:  Minerva Stomatol        ISSN: 0026-4970


  3 in total

1.  Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses.

Authors:  Abdul Rahman Alkharrat; Marc Schmitter; Stefan Rues; Peter Rammelsberg
Journal:  Clin Oral Investig       Date:  2017-12-02       Impact factor: 3.573

2.  Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic.

Authors:  Suk-Ho Kang; Juhea Chang; Ho-Hyun Son
Journal:  Restor Dent Endod       Date:  2013-08-23

3.  Orthodontic bonding to silicate ceramics: impact of different pretreatment methods on shear bond strength between ceramic restorations and ceramic brackets.

Authors:  Rebecca Jungbauer; Christian Kirschneck; Christian M Hammer; Peter Proff; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2021-11-18       Impact factor: 3.573

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.