Literature DB >> 21666290

Implant strategies for endocervical and interstitial ultrasound hyperthermia adjunct to HDR brachytherapy for the treatment of cervical cancer.

Jeffery H Wootton1, Punit Prakash, I-Chow Joe Hsu, Chris J Diederich.   

Abstract

Catheter-based ultrasound devices provide a method to deliver 3D conformable heating integrated with HDR brachytherapy delivery. Theoretical characterization of heating patterns was performed to identify implant strategies for these devices which can best be used to apply hyperthermia to cervical cancer. A constrained optimization-based hyperthermia treatment planning platform was used for the analysis. The proportion of tissue ≥41 °C in a hyperthermia treatment volume was maximized with constraints T(max) ≤ 47 °C, T(rectum) ≤ 41.5 °C, and T(bladder) ≤ 42.5 °C. Hyperthermia treatment was modeled for generalized implant configurations and complex configurations from a database of patients (n = 14) treated with HDR brachytherapy. Various combinations of endocervical (360° or 2 × 180° output; 6 mm OD) and interstitial (180°, 270°, or 360° output; 2.4 mm OD) applicators within catheter locations from brachytherapy implants were modeled, with perfusion constant (1 or 3 kg m(-3) s(-1)) or varying with location or temperature. Device positioning, sectoring, active length and aiming were empirically optimized to maximize thermal coverage. Conformable heating of appreciable volumes (>200 cm(3)) is possible using multiple sectored interstitial and endocervical ultrasound devices. The endocervical device can heat >41 °C to 4.6 cm diameter compared to 3.6 cm for the interstitial. Sectored applicators afford tight control of heating that is robust to perfusion changes in most regularly spaced configurations. T(90) in example patient cases was 40.5-42.7 °C (1.9-39.6 EM(43 °C)) at 1 kg m(-3) s(-1) with 10/14 patients ≥41 °C. Guidelines are presented for positioning of implant catheters during the initial surgery, selection of ultrasound applicator configurations, and tailored power schemes for achieving T(90) ≥ 41 °C in clinically practical implant configurations. Catheter-based ultrasound devices, when adhering to the guidelines, show potential to generate conformal therapeutic heating ranging from a single endocervical device targeting small volumes local to the cervix (<2 cm radial) to a combination of a 2 × 180° endocervical and directional interstitial applicators in the lateral periphery to target much larger volumes (6 cm radial), while preferentially limiting heating of the bladder and rectum.

Entities:  

Mesh:

Year:  2011        PMID: 21666290     DOI: 10.1088/0031-9155/56/13/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Development of a spherically focused phased array transducer for ultrasonic image-guided hyperthermia.

Authors:  Jingfei Liu; Josquin Foiret; Douglas N Stephens; Olivier Le Baron; Katherine W Ferrara
Journal:  Phys Med Biol       Date:  2016-06-29       Impact factor: 3.609

Review 2.  Ultrasound Hyperthermia Technology for Radiosensitization.

Authors:  Lifei Zhu; Michael B Altman; Andrei Laszlo; William Straube; Imran Zoberi; Dennis E Hallahan; Hong Chen
Journal:  Ultrasound Med Biol       Date:  2019-02-14       Impact factor: 2.998

Review 3.  Novel agents and treatment techniques to enhance radiotherapeutic outcomes in carcinoma of the uterine cervix.

Authors:  Ajeet Kumar Gandhi
Journal:  Ann Transl Med       Date:  2016-02

4.  Dual-sectored transurethral ultrasound for thermal treatment of stress urinary incontinence: in silico studies in 3D anatomical models.

Authors:  Dong Liu; Matthew Adams; E Clif Burdette; Chris J Diederich
Journal:  Med Biol Eng Comput       Date:  2020-04-10       Impact factor: 2.602

5.  Multiple applicator hepatic ablation with interstitial ultrasound devices: theoretical and experimental investigation.

Authors:  Punit Prakash; Vasant A Salgaonkar; E Clif Burdette; Chris J Diederich
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

Review 6.  Catheter-based ultrasound technology for image-guided thermal therapy: current technology and applications.

Authors:  Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2015-03-23       Impact factor: 3.914

7.  Thermal therapy of pancreatic tumours using endoluminal ultrasound: Parametric and patient-specific modelling.

Authors:  Matthew S Adams; Serena J Scott; Vasant A Salgaonkar; Graham Sommer; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2016-01-21       Impact factor: 3.914

8.  Approaches for modelling interstitial ultrasound ablation of tumours within or adjacent to bone: theoretical and experimental evaluations.

Authors:  Serena J Scott; Punit Prakash; Vasant Salgaonkar; Peter D Jones; Richard N Cam; Misung Han; Viola Rieke; E Clif Burdette; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2013-11       Impact factor: 3.914

9.  Interstitial ultrasound ablation of vertebral and paraspinal tumours: parametric and patient-specific simulations.

Authors:  Serena J Scott; Vasant Salgaonkar; Punit Prakash; E Clif Burdette; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2014-06       Impact factor: 3.914

Review 10.  Modelling of endoluminal and interstitial ultrasound hyperthermia and thermal ablation: applications for device design, feedback control and treatment planning.

Authors:  Punit Prakash; Vasant A Salgaonkar; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2013-06       Impact factor: 3.914

View more