Determination of inadvertent atrial capture during para-Hisian pacing.

Manoj Obeyesekere1, Peter Leong-Sit, Allan Skanes, Andrew Krahn, Raymond Yee, Lorne J Gula, Matthew Bennett, George J Klein.   

Abstract

BACKGROUND: Inadvertent capture of the atrium will lead to spurious results during para-Hisian pacing. We sought to establish whether the stimulation-to-atrial electrogram interval at the proximal coronary sinus (stim-PCS) or high right atrium (stim-HRA) could signal inadvertent atrial capture. METHODS AND
RESULTS: Para-Hisian pacing with and without intentional atrial capture was performed in 31 patients. Stim-HRA and stim-PCS intervals were measured with atrial capture, His plus para-Hisian ventricular (H+V) capture, and para-Hisian ventricular (V) capture alone. The mean stim-HRA interval was significantly shorter with atrial capture (66 ± 18 ms) than with H+V (121 ± 27 ms, P < 0.001) or V capture alone (174 ± 38 ms, P < 0.001). The mean stim-PCS interval was significantly shorter with atrial capture (51 ± 16 ms) than with H+V (92 ± 22 ms, P<0.001) or V capture alone (146 ± 33 ms, P < 0.001). A stim-PCS < 60 ms (stim-HRA < 70 ms) was observed only with atrial capture. A stim-PCS >90 ms (stim-HRA >100 ms) was observed only in the absence of atrial capture. A stim-HRA of < 85 ms was highly specific and stim-PCS of < 85 ms highly sensitive at identifying atrial capture. Stim-HRA intervals of 75 to 97 ms and stim-PCS intervals of 65 to 88 ms were observed with either atrial, His, or para-Hisian ventricular capture without atrial capture. In this overlap zone, all patients demonstrated a stim-PCS or stim-HRA interval prolongation of at least 20 ms when the catheter was advanced to avoid deliberate atrial pacing. The QRS morphology was of limited value in distinguishing atrial capture due to concurrent ventricular or H+V capture, as observed in 20 of 31 (65%) patients.
CONCLUSIONS: Stim-PCS and stim-HRA intervals can be used to monitor for inadvertent atrial capture during para-Hisian pacing. A stim-PCS < 60 ms (or stim-HRA < 70 ms) and stim-PCS > 90 ms (or stim-HRA > 100 ms) were observed only with and without atrial capture, respectively, but there was significant overlap between these values. Deliberate atrial capture and loss of capture reliably identifies atrial capture regardless of intervals.

Entities:  

Mesh:

Year:  2011        PMID: 21665982     DOI: 10.1161/CIRCEP.111.963058

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  2 in total

Review 1.  Parahisian pacing: technique, utility, and pitfalls.

Authors:  Seth H Sheldon; Hung-Kei Li; Samuel J Asirvatham; Christopher J McLeod
Journal:  J Interv Card Electrophysiol       Date:  2014-06-11       Impact factor: 1.900

2.  His bundle capture proximal to the site of bundle branch block: A novel pitfall of the para-Hisian pacing maneuver.

Authors:  Marek Jastrzebski; Piotr Kukla; Danuta Czarnecka
Journal:  HeartRhythm Case Rep       Date:  2017-11-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.