| Literature DB >> 21665911 |
G Scrascia1, P Guida, C Rotunno, M De Palo, F Mastro, A Pignatelli, L de Luca Tupputi Schinosa, D Paparella.
Abstract
The ideal cardioplegic strategy in thoracic aorta operations requiring long cardiopulmonary bypass and cross-clamp time has not been established. Suboptimal myocardial protection may lead to myocardial damage and possible post-operative complications. We evaluate post-operative cardiac Troponin I (cTnI) release, low cardiac output syndrome (LCOS) and mortality, using a cold crystalloid single-dose intracellular or cold blood multidose cardioplegia in 112 elective or emergent thoracic aorta operation patients. Fifty-four patients (HTK group) received Custodiol® cardioplegic solution and 58 received cold blood cardioplegia (CB group). Cross-clamp time, cardiopulmonary bypass (CPB) time and cTnI peak release were similar in both groups. No differences were found for atrial and ventricular arrhythmias, inotropic support, LCOS and in-hospital mortality. Two-way ANOVA analysis revealed an interactive effect on cTnI peak (p=0.012) of cardioplegic solution type across the cross-clamp time quintile. In the fifth quintile, cross-clamp time patient (>160 min) cTnI peak value was higher in CB patients (p=0.044). HTK and CB cardioplegic solutions assure similar myocardial protection in patients undergoing thoracic aorta operations. In long cross-clamp times, the lower post-operative cTnI release detected using HTK may be indicative of a better myocardial protection in these extreme conditions.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21665911 DOI: 10.1177/0267659111409276
Source DB: PubMed Journal: Perfusion ISSN: 0267-6591 Impact factor: 1.972