Literature DB >> 21665162

Accuracy of ultrasound-guided and palpation-guided knee injections by an experienced and less-experienced injector using a superolateral approach: a cadaveric study.

Heather M Curtiss1, Jonathan T Finnoff, Evan Peck, John Hollman, Jeff Muir, Jay Smith.   

Abstract

OBJECTIVES: To evaluate the accuracy of ultrasound (US)-guided and palpation-guided knee injections by an experienced and a less-experienced clinician with use of a superolateral approach.
DESIGN: Single-blinded, prospective study.
SETTING: Academic institution procedural skills laboratory. PARTICIPANTS: Twenty cadaveric knee specimens without trauma, surgery, or major deformity. INTERVENTION: US-guided and palpation-guided knee injections of colored liquid latex were performed in each specimen by an experienced and a less-experienced clinician with use of a superolateral approach. The order of injections was randomized. The specimens were subsequently dissected by a blinded investigator and assessed for accuracy. MAIN OUTCOMES: Accuracy was divided into 3 categories: (1) accurate (all of the injectate was within the joint), (2) partially accurate (some of the injectate was within the joint and some was within the periarticular tissues), and (3) inaccurate (none of the injectate was within the joint). The accuracy rates were calculated for each clinician and guidance method.
RESULTS: US-guided knee injections that used a superolateral approach were 100% accurate for both clinicians. Palpation-guided knee injections that used a superolateral approach were significantly influenced by experience, with the less-experienced investigator demonstrating an accuracy rate of 55% (95% confidence interval = 34%-74%) and the more experienced investigator demonstrating an accuracy rate of 100% (95% confidence interval = 81%-100%).
CONCLUSIONS: US-guided knee injections that use a superolateral approach are very accurate in a cadaveric model, whereas the accuracy of palpation-guided knee injections that use the same approach is variable and appears to be significantly influenced by clinician experience. These findings suggest that US guidance should be considered when one performs knee injections with a superolateral approach that require a high degree of accuracy.
Copyright © 2011 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21665162     DOI: 10.1016/j.pmrj.2011.02.020

Source DB:  PubMed          Journal:  PM R        ISSN: 1934-1482            Impact factor:   2.298


  12 in total

1.  Resident Accuracy of Electromyography Needle Electrode Placement Using Ultrasound Verification.

Authors:  Kristopher Karvelas; Craig Ziegler; Monica E Rho
Journal:  PM R       Date:  2015-12-12       Impact factor: 2.298

2.  Accuracy of Ultrasound-Guided versus Landmark-Guided Intra-articular Injection for Rat Knee Joints.

Authors:  Amparo Ruiz; Dalibel Bravo; Alejandra Duarte; Ronald S Adler; José G Raya
Journal:  Ultrasound Med Biol       Date:  2019-07-19       Impact factor: 2.998

3.  The "injection jet sign": an innovative method of needle position confirmation during ultrasound guided injections.

Authors:  Judah Goldschmiedt; Chaitanya Shilagani; Himanshu Patel
Journal:  Skeletal Radiol       Date:  2017-01-27       Impact factor: 2.199

Review 4.  Clinical utility of ultrasound guidance for intra-articular knee injections: a review.

Authors:  David J Berkoff; Larry E Miller; Jon E Block
Journal:  Clin Interv Aging       Date:  2012-03-20       Impact factor: 4.458

Review 5.  Existing Evidence on Ultrasound-Guided Injections in Sports Medicine.

Authors:  Eldra W Daniels; David Cole; Bret Jacobs; Shawn F Phillips
Journal:  Orthop J Sports Med       Date:  2018-02-22

6.  Efficacy of a non-image-guided diagnostic hip injection in patients with clinical and radiographic evidence of intra-articular hip pathology.

Authors:  Matthew J Kraeutler; Tigran Garabekyan; Matthew J Fioravanti; David A Young; Omer Mei-Dan
Journal:  J Hip Preserv Surg       Date:  2018-05-03

7.  Accuracy of long head of the biceps tendon palpation by physical therapists; an ultrasonographic study.

Authors:  Amy W McDevitt; Joshua A Cleland; Colin Strickland; Paul Mintken; Mary Becky Leibold; Maria Borg; Rebecca Altic; Suzanne Snodgrass
Journal:  J Phys Ther Sci       Date:  2020-11-11

8.  Sonoanatomic variation of pes anserine bursa.

Authors:  Farnad Imani; Poupak Rahimzadeh; Farid Abolhasan Gharehdag; Seyed Hamid Reza Faiz
Journal:  Korean J Pain       Date:  2013-07-01

Review 9.  Where and how to inject the knee--a systematic review.

Authors:  Nasimah Maricar; Matthew J Parkes; Michael J Callaghan; David T Felson; Terence W O'Neill
Journal:  Semin Arthritis Rheum       Date:  2013-10       Impact factor: 5.532

10.  Tolerability and Efficacy of 3 Approaches to Intra-articular Corticosteroid Injections of the Knee for Osteoarthritis: A Randomized Controlled Trial.

Authors:  Bradford S Wagner; Allyson S Howe; William W Dexter; John R Hatzenbuehler; Christina Holt; Amy E Haskins; F Lee Lucas
Journal:  Orthop J Sports Med       Date:  2015-08-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.