Literature DB >> 21664386

Development and validation of ELISA for detection of antibodies to Legionella pneumophila serogroup 1, 3 and 6 in human sera.

Pernille L Elverdal1, Christina W Svarrer, Charlotte S Jørgensen, Ian C Skovsted, Søren A Uldum.   

Abstract

The aim of this study was to determine whether separate measurement of immunoglobulin (Ig) M and G antibodies to Legionella (L.) pneumophila serogroups (sg) 1, 3 and 6 as single antigens can facilitate an early diagnosis of Legionnaires' disease. The developed ELISA was evaluated and compared with an in-house indirect Legionella immunofluorescence antibody test (IFAT) measuring Total Ig. A total of 193 sera from 128 patients with confirmed L. pneumophila infections were used to assess the sensitivity of the developed ELISA. The sensitivity was assessed in different time-periods after onset of symptoms. It was found that the sensitivity of the test increased during the first month of infection, IgM being the most sensitive; ranging from 13% in the first week after onset of symptoms, 45% in the second week to 84% in the third week; in the fourth (and beyond) week a drop to 67% was observed. The IFAT detecting L. pneumophila sg 1-6 had a sensitivity of 11%, 27%, 80% and 59%, respectively, during these time-periods. The test with the lowest sensitivity was the IgG ELISA (0%, 21%, 36% and 52%), but by combining the IgG results with the IgM results, the overall sensitivity of the assay was improved (13%, 48%, 88% and 70%). This study confirms that detection of IgG and IgM antibodies by ELISA is an important diagnostic tool especially during the initial phase of the disease, when supported by other tests like the urinary antigen test, PCR or culture. Furthermore, we showed that the ELISA is suitable for the detection of significant changes in antibody levels in paired serum samples. It was found that the sensitivity was higher for the ELISA assays than for the IFAT. Both the in-house IgM ELISA and the IFAT had a low false positive rate, while a 14% false positive rate was found for the IgG ELISA among serum samples from patients with other infections.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21664386     DOI: 10.1016/j.mimet.2011.05.022

Source DB:  PubMed          Journal:  J Microbiol Methods        ISSN: 0167-7012            Impact factor:   2.363


  2 in total

1.  Detection of Legionella bozemanae, a new cause of septic arthritis, by PCR followed by specific culture.

Authors:  Søren Andreas Just; John Bonde Knudsen; Søren Anker Uldum; Hanne Marie Holt
Journal:  J Clin Microbiol       Date:  2012-10-10       Impact factor: 5.948

2.  Case Report: Metagenomic Next-Generation Sequencing in Diagnosis of Legionella pneumophila Pneumonia in a Patient After Umbilical Cord Blood Stem Cell Transplantation.

Authors:  Yangyan Wang; Yuanyuan Dai; Huaiwei Lu; Wenjiao Chang; Fan Ma; Ziran Wang; Zhican Liu; Xiaoling Ma
Journal:  Front Med (Lausanne)       Date:  2021-06-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.