Minimizing the number of voltage sources and fluid reservoirs for electrokinetic valving in microfluidic devices.

S C Jacobson1, S V Ermakov, J M Ramsey.   

Abstract

A microchip gated valve is demonstrated that uses a single voltage source and three fluid reservoirs. The fluidic valve is a cross intersection, and the channels are dimensioned to perform the appropriate voltage division, simplifying the voltage control hardware. A single voltage source is applied directly to the sample reservoir and through a high-voltage relay to the buffer reservoir, and the waste reservoir is grounded. The volume of sample dispensed is determined by the duration that the high-voltage relay is open. Volumetric reproducibility is demonstrated to be <0.5% relative standard deviation for volumes of ≥20 pL. The valve is tested for the minimum applied voltage necessary for leakage-free operation, i.e., sample diffusing from the cross intersection into the analysis channel. Moreover, appropriate channel dimensions are used to minimize the number of fluid reservoirs allowing effluent from the analysis and waste channels to be combined into a single reservoir.

Year:  1999        PMID: 21662916     DOI: 10.1021/ac990059s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  14 in total

1.  Gray-scale photolithography using microfluidic photomasks.

Authors:  Chihchen Chen; Danny Hirdes; Albert Folch
Journal:  Proc Natl Acad Sci U S A       Date:  2003-02-06       Impact factor: 11.205

2.  Dynamic monitoring of glucagon secretion from living cells on a microfluidic chip.

Authors:  Jonathan G Shackman; Kendra R Reid; Colleen E Dugan; Robert T Kennedy
Journal:  Anal Bioanal Chem       Date:  2012-03       Impact factor: 4.142

3.  Microfluidic serial dilution circuit.

Authors:  Brian M Paegel; William H Grover; Alison M Skelley; Richard A Mathies; Gerald F Joyce
Journal:  Anal Chem       Date:  2006-11-01       Impact factor: 6.986

4.  Optimization of a microfluidic electrophoretic immunoassay using a Peltier cooler.

Authors:  Nikita Mukhitov; Lian Yi; Adrian M Schrell; Michael G Roper
Journal:  J Chromatogr A       Date:  2014-09-22       Impact factor: 4.759

5.  Integrated perfusion and separation systems for entrainment of insulin secretion from islets of Langerhans.

Authors:  Lian Yi; Xue Wang; Raghuram Dhumpa; Adrian M Schrell; Nikita Mukhitov; Michael G Roper
Journal:  Lab Chip       Date:  2015-02-07       Impact factor: 6.799

6.  Continuous operation of microfabricated electrophoresis devices for 24 hours and application to chemical monitoring of living cells.

Authors:  Kendra R Reid; Robert T Kennedy
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

7.  Surface Modification of Glass/PDMS Microfluidic Valve Assemblies Enhances Valve Electrical Resistance.

Authors:  Xuemin Wang; Mark T Agasid; Christopher A Baker; Craig A Aspinwall
Journal:  ACS Appl Mater Interfaces       Date:  2019-09-09       Impact factor: 9.229

8.  Quantitative monitoring of insulin secretion from single islets of Langerhans in parallel on a microfluidic chip.

Authors:  John F Dishinger; Kendra R Reid; Robert T Kennedy
Journal:  Anal Chem       Date:  2009-04-15       Impact factor: 6.986

9.  Microfluidic chip for high efficiency electrophoretic analysis of segmented flow from a microdialysis probe and in vivo chemical monitoring.

Authors:  Meng Wang; Gregory T Roman; Maura L Perry; Robert T Kennedy
Journal:  Anal Chem       Date:  2009-11-01       Impact factor: 6.986

10.  Simultaneous monitoring of insulin and islet amyloid polypeptide secretion from islets of Langerhans on a microfluidic device.

Authors:  Anna R Lomasney; Lian Yi; Michael G Roper
Journal:  Anal Chem       Date:  2013-07-30       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.