Literature DB >> 21656563

Whole-heart coronary MR angiography with 2D self-navigated image reconstruction.

Markus Henningsson1, Peter Koken, Christian Stehning, Reza Razavi, Claudia Prieto, René M Botnar.   

Abstract

Several self-navigation techniques have been proposed to improve respiratory motion compensation in coronary MR angiography. In this work, we implemented a 2D self-navigation method by using the startup profiles of a whole-heart balanced Steady-state free precession sequence, which are primarily used to catalyze the magnetization towards the steady-state. To create 2D self-navigation images (2DSN), we added phase encoding gradients to the startup profiles. With this approach we calculated foot-head and left-right motion and performed retrospective translational motion correction. The 2DSN images were reconstructed from 10 startup profiles acquired at the beginning of each shot. Nine healthy subjects were scanned, and the proposed method was compared to a 1D self-navigation (1DSN) method with foot-head correction only. Foot-head correction was also performed with the diaphragmatic 1D pencil beam navigator (1Dnav) using a tracking factor of 0.6. 2DSN shows improved motion correction compared to 1DSN and 1Dnav for all coronary arteries and all subjects for the investigated diaphragmatic gating window of 10 mm. The visualized vessel length of the right coronary artery could be significantly improved with a multiple targeted 2D self-navigation approach, compared to 2DSN method.
Copyright © 2011 Wiley Periodicals, Inc.

Mesh:

Year:  2011        PMID: 21656563     DOI: 10.1002/mrm.23027

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  64 in total

1.  Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging.

Authors:  Holden H Wu; Paul T Gurney; Bob S Hu; Dwight G Nishimura; Michael V McConnell
Journal:  Magn Reson Med       Date:  2012-05-30       Impact factor: 4.668

Review 2.  Update on the Role of Cardiac Magnetic Resonance Imaging in Congenital Heart Disease.

Authors:  Prabhakar Rajiah; Animesh Tandon; Gerald F Greil; Suhny Abbara
Journal:  Curr Treat Options Cardiovasc Med       Date:  2017-01

3.  Four-dimensional respiratory motion-resolved whole heart coronary MR angiography.

Authors:  Davide Piccini; Li Feng; Gabriele Bonanno; Simone Coppo; Jérôme Yerly; Ruth P Lim; Juerg Schwitter; Daniel K Sodickson; Ricardo Otazo; Matthias Stuber
Journal:  Magn Reson Med       Date:  2016-03-28       Impact factor: 4.668

4.  3D image-based navigators for coronary MR angiography.

Authors:  Nii Okai Addy; R Reeve Ingle; Jieying Luo; Corey A Baron; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

Review 5.  Cardiovascular magnetic resonance imaging for structural heart disease.

Authors:  Yiling Situ; Samuel C M Birch; Camila Moreyra; Cameron J Holloway
Journal:  Cardiovasc Diagn Ther       Date:  2020-04

6.  Nonrigid autofocus motion correction for coronary MR angiography with a 3D cones trajectory.

Authors:  R Reeve Ingle; Holden H Wu; Nii Okai Addy; Joseph Y Cheng; Phillip C Yang; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

7.  Utility of respiratory-navigator-rejected k-space lines for improved signal-to-noise ratio in three-dimensional cardiac MR.

Authors:  Mehmet Akçakaya; Jaime L Shaw; Thomas H Hauser; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-12-11       Impact factor: 4.668

8.  5D whole-heart sparse MRI.

Authors:  Li Feng; Simone Coppo; Davide Piccini; Jerome Yerly; Ruth P Lim; Pier Giorgio Masci; Matthias Stuber; Daniel K Sodickson; Ricardo Otazo
Journal:  Magn Reson Med       Date:  2017-05-11       Impact factor: 4.668

9.  Improved respiratory self-navigation for 3D radial acquisitions through the use of a pencil-beam 2D-T2 -prep for free-breathing, whole-heart coronary MRA.

Authors:  Andrew J Coristine; Jerome Chaptinel; Giulia Ginami; Gabriele Bonanno; Simone Coppo; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  Magn Reson Med       Date:  2017-05-31       Impact factor: 4.668

10.  High efficiency coronary MR angiography with nonrigid cardiac motion correction.

Authors:  Jianing Pang; Yuhua Chen; Zhaoyang Fan; Christopher Nguyen; Qi Yang; Yibin Xie; Debiao Li
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.