Literature DB >> 21656033

Fabrication and characterization of bioactive composite coatings on Mg-Zn-Ca alloy by MAO/sol-gel.

J H Gao1, X Y Shi, B Yang, S S Hou, E C Meng, F X Guan, S K Guan.   

Abstract

High corrosion rate and accumulation of hydrogen gas upon degradation impede magnesium alloys' clinical application as implants. In this work, micro-arc oxidation (MAO) was used to fabricate a porous coating on magnesium alloys as an intermediate layer to enhance the bonding strength of propolis layer. Then the composite coatings were fabricated using sol-gel method by dipping sample into the solution containing propolis and polylactic acid at 40 °C. The corrosion resistance of the samples was determined based on potentiodynamic polarization experiments and immersion tests. Biocompatibility was designed by observing the attachment and growth of wharton's jelly-derived mesenchymal stem cells (WJCs) on substrates with MAO coating and substrates with composite coatings. The results showed that, compared with that of Mg-Zn-Ca alloy, the corrosion current density of the samples with composite coatings decreased from 5.37 × 10⁻⁵ to 1.10 × 10⁻⁶ A/cm² and the corrosion potential increased by 240 mV. Composite coatings exhibit homogeneous corrosion behavior and can promote WJCs cell adhesion and proliferation. In the meantime, pH value was relatively stable during the immersion tests, which may be significant for cellular survival. In conclusion, our results indicate that composite coatings on Mg-Zn-Ca alloy fabricated by MAO/sol-gel method provide a new type bioactive material.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21656033     DOI: 10.1007/s10856-011-4349-9

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  12 in total

1.  In vitro responses of human bone marrow stromal cells to a fluoridated hydroxyapatite coated biodegradable Mg-Zn alloy.

Authors:  Jianan Li; Yang Song; Shaoxiang Zhang; Changli Zhao; Fan Zhang; Xiaonong Zhang; Lei Cao; Qiming Fan; Tingting Tang
Journal:  Biomaterials       Date:  2010-05-10       Impact factor: 12.479

2.  National Nosocomial Infections Surveillance (NNIS) System Report, data summary from January 1992 through June 2004, issued October 2004.

Authors: 
Journal:  Am J Infect Control       Date:  2004-12       Impact factor: 2.918

Review 3.  How useful is SBF in predicting in vivo bone bioactivity?

Authors:  Tadashi Kokubo; Hiroaki Takadama
Journal:  Biomaterials       Date:  2006-01-31       Impact factor: 12.479

4.  Microstructure and corrosion properties of as sub-rapid solidification Mg-Zn-Y-Nd alloy in dynamic simulated body fluid for vascular stent application.

Authors:  Jun Wang; Liguo Wang; Shaokang Guan; Shijie Zhu; Chenxing Ren; Shusen Hou
Journal:  J Mater Sci Mater Med       Date:  2010-03-30       Impact factor: 3.896

Review 5.  Magnesium and its alloys as orthopedic biomaterials: a review.

Authors:  Mark P Staiger; Alexis M Pietak; Jerawala Huadmai; George Dias
Journal:  Biomaterials       Date:  2005-10-24       Impact factor: 12.479

6.  Comparison of mesenchymal stem cell and osteosarcoma cell adhesion to hydroxyapatite.

Authors:  Shikhar Vohra; Kristin M Hennessy; Amber A Sawyer; Ya Zhuo; Susan L Bellis
Journal:  J Mater Sci Mater Med       Date:  2008-07-15       Impact factor: 3.896

Review 7.  Wharton's jelly-derived cells are a primitive stromal cell population.

Authors:  Deryl L Troyer; Mark L Weiss
Journal:  Stem Cells       Date:  2007-12-06       Impact factor: 6.277

8.  In vivo corrosion and corrosion protection of magnesium alloy LAE442.

Authors:  F Witte; J Fischer; J Nellesen; C Vogt; J Vogt; T Donath; F Beckmann
Journal:  Acta Biomater       Date:  2009-10-12       Impact factor: 8.947

9.  In vitro and in vivo evaluation of the surface bioactivity of a calcium phosphate coated magnesium alloy.

Authors:  Liping Xu; Feng Pan; Guoning Yu; Lei Yang; Erlin Zhang; Ke Yang
Journal:  Biomaterials       Date:  2008-12-27       Impact factor: 12.479

Review 10.  Concise review: human umbilical cord stroma with regard to the source of fetus-derived stem cells.

Authors:  Alp Can; Sercin Karahuseyinoglu
Journal:  Stem Cells       Date:  2007-08-09       Impact factor: 6.277

View more
  3 in total

1.  Investigation on the in vitro cytocompatibility of Mg-Zn-Y-Nd-Zr alloys as degradable orthopaedic implant materials.

Authors:  Xiaozhe Song; Lei Chang; Jun Wang; Shijie Zhu; Liguo Wang; Kun Feng; Yage Luo; Shaokang Guan
Journal:  J Mater Sci Mater Med       Date:  2018-03-30       Impact factor: 3.896

2.  The influence of MgH2 on the assessment of electrochemical data to predict the degradation rate of Mg and Mg alloys.

Authors:  Wolf-Dieter Mueller; Helga Hornberger
Journal:  Int J Mol Sci       Date:  2014-06-26       Impact factor: 5.923

3.  Similarities and differences in coatings for magnesium-based stents and orthopaedic implants.

Authors:  Jun Ma; Marc Thompson; Nan Zhao; Donghui Zhu
Journal:  J Orthop Translat       Date:  2014-04-05       Impact factor: 5.191

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.