Literature DB >> 21655378

Reliability and exploration of the side-lying thoraco-lumbar rotation measurement (strm).

Brian D Iveson, Sherry L McLaughlin, R Heath Todd, J Parry Gerber.   

Abstract

STUDY
DESIGN: Clinical Measurement, Reliability, Descriptive Study
OBJECTIVES: To establish intrarater and interrater reliability of the Side-lying Thoraco-lumbar Rotation Measurement (STRM) and to explore frequencies and magnitude of rotational differences that exist in various musculoskeletal conditions.
BACKGROUND: Limitation in thoracic rotation could lead to increased motion at adjacent areas (i.e., shoulders and low back). This could potentially lead to excessive strain and subsequent injury from repetitive stress. Currently, there is no well-established method to reliably measure and objectively quantify thoraco-lumbar spine rotation.
METHODS: Intrarater reliability was assessed by a single investigator performing three STRM measurements on 10 participants on two consecutive days. Interrater reliability was assessed by two independent examiners, performing the STRM on 30 participants. Reliability was assessed using the intraclass correlation coefficient (ICC) statistic. To explore the incidence and magnitude of side-to-side thoraco-lumbar rotation differences, the STRM was measured on 156 participants of various musculoskeletal conditions.
RESULTS: The intrarater reliability of the STRM was excellent (ICC=.94). The interrater reliability was good (ICC=.88). Fifty four percent of the sample exhibited greater than a 10% side-to-side difference in the STRM while twenty percent exhibited greater than a 20% side-to-side difference.
CONCLUSION: The STRM can be used as a reliable and objective method to quantify thoraco-lumbar spine rotation. It also appears that a large percentage of patients with varied musculoskeletal complaints may have greater than a 10-20% asymmetry in spinal rotational movement. Future research is needed to determine the clinical applicability and relevance of these findings. LEVEL OF EVIDENCE: 4.

Entities:  

Keywords:  Thoraco-lumbar rotation; reliability

Year:  2010        PMID: 21655378      PMCID: PMC3096141     

Source DB:  PubMed          Journal:  N Am J Sports Phys Ther        ISSN: 1558-6162


  6 in total

1.  Regional interdependence: a musculoskeletal examination model whose time has come.

Authors:  Robert S Wainner; Julie M Whitman; Joshua A Cleland; Timothy W Flynn
Journal:  J Orthop Sports Phys Ther       Date:  2007-11       Impact factor: 4.751

2.  Effects of pelvic asymmetry and low back pain on trunk kinematics during sitting: a comparison with standing.

Authors:  Einas Al-Eisa; David Egan; Kevin Deluzio; Richard Wassersug
Journal:  Spine (Phila Pa 1976)       Date:  2006-03-01       Impact factor: 3.468

3.  Comparison of supervised exercise with and without manual physical therapy for patients with shoulder impingement syndrome.

Authors:  M D Bang; G D Deyle
Journal:  J Orthop Sports Phys Ther       Date:  2000-03       Impact factor: 4.751

4.  Manipulative therapy in addition to usual medical care for patients with shoulder dysfunction and pain: a randomized, controlled trial.

Authors:  Gert J D Bergman; Jan C Winters; Klaas H Groenier; Jan J M Pool; Betty Meyboom-de Jong; Klaas Postema; Geert J M G van der Heijden
Journal:  Ann Intern Med       Date:  2004-09-21       Impact factor: 25.391

5.  Reliability and concurrent validity of the BROM II for measuring lumbar mobility.

Authors:  J Breum; J Wiberg; J E Bolton
Journal:  J Manipulative Physiol Ther       Date:  1995-10       Impact factor: 1.437

6.  Short-term effects of thrust versus nonthrust mobilization/manipulation directed at the thoracic spine in patients with neck pain: a randomized clinical trial.

Authors:  Joshua A Cleland; Paul Glynn; Julie M Whitman; Sarah L Eberhart; Cameron MacDonald; John D Childs
Journal:  Phys Ther       Date:  2007-03-06
  6 in total
  2 in total

1.  Exploration of the y-balance test for assessment of upper quarter closed kinetic chain performance.

Authors:  Richard B Westrick; Joseph M Miller; Scott D Carow; J Parry Gerber
Journal:  Int J Sports Phys Ther       Date:  2012-04

2.  Reliability and concurrent validity of the iPhone® Compass application to measure thoracic rotation range of motion (ROM) in healthy participants.

Authors:  James Furness; Ben Schram; Alistair J Cox; Sarah L Anderson; Justin Keogh
Journal:  PeerJ       Date:  2018-03-08       Impact factor: 2.984

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.