The use of the StarClose device for obtaining femoral artery hemostasis.

Ariel Rodriguez1, Steven G Katz.   

Abstract

BACKGROUND: Following percutaneous intervention, obtaining femoral artery hemostasis quickly and reliably with few complications is of considerable importance. While the StarClose device has been studied in patients undergoing cardiac catheterization, its use in patients undergoing treatment for peripheral vascular disease has rarely been reported. It is the purpose of this report to determine whether the Starclose is able to deliver safe and effective femoral artery closure in this group of patients.
METHODS: The records of all patients undergoing StarClose closure of the femoral artery by or under the supervision of a single vascular surgeon were reviewed. Indication, type of intervention, and size of the vascular sheath employed were noted. Times to mobilization and discharge were tabulated. Complications including hemorrhage, pseudoaneurysm, infection, and vessel occlusion were recorded.
RESULTS: Between February 2006 and September 2009, 603 StarClose nitinol clip closure devices were deployed in 478 patients. In all, 97 procedures were diagnostic and 506 included therapeutic interventions. A total of 97 5F sheaths, 465 6F sheaths, and 41 7F sheaths were employed. Time to ambulation and discharge was 44.2 ± 13.2 minutes and 119.3 ± 22.6 minutes in patients in whom a 5F sheath was used, 112.5 ± 13.5 minutes and 157.5 ± 20.6 minutes when a 6F sheath was used, and 121.9+/-38.8 minutes and 160.2+/-43.2 minutes when a 7F sheath was employed. The clip could not be successfully deployed in 21 arteries (3.5%) and manual compression was successful in achieving hemostasis in 17 patients without complication. Three patients (0.5%) developed major hematomas requiring transfusion; 1 patient developed a pseudoaneurysm (0.17%) requiring thrombin injection. A single patient (0.17%) occluded his common femoral artery following StarClose deployment and 1 patient (0.17%) developed a femoral artery stenosis requiring balloon dilatation. No patient developed a groin infection.
CONCLUSIONS: The StarClose provides a safe and reliable method of achieving femoral artery closure following percutaneous intervention for peripheral arterial disease. When successfully deployed, it allows for early ambulation and discharge. Since it remains entirely extraluminal, it offers advantages over other closure devices and can be safely used in the vast majority of patients with peripheral vascular disease.

Entities:  

Mesh:

Year:  2011        PMID: 21646232     DOI: 10.1177/1538574411410327

Source DB:  PubMed          Journal:  Vasc Endovascular Surg        ISSN: 1538-5744            Impact factor:   1.089


  6 in total

Review 1.  Access and hemostasis: femoral and popliteal approaches and closure devices-why, what, when, and how?

Authors:  Iacopo Barbetta; Jos C van den Berg
Journal:  Semin Intervent Radiol       Date:  2014-12       Impact factor: 1.513

2.  Arterial closure device to achieve hemostasis in children following percutaneous femoral arterial puncture.

Authors:  Somnath J Prabhu; Siddharth A Padia; Karim Valji; Michael F McNeeley; Sandeep Vaidya; Nghia J Vo
Journal:  Pediatr Radiol       Date:  2013-01-16

3.  Nitinol clip distal migration and resultant popliteo-tibial artery occlusion complicating access closure by the StarClose SE vascular closure system.

Authors:  Dae Han Choi; Myeong Jin Kim; Chan Jong Yoo; Cheol Wan Park
Journal:  BMJ Case Rep       Date:  2016-03-30

4.  Acute limb ischemia caused by incorrect deployment of a clip-based arterial closure device.

Authors:  Łukasz Dzieciuchowicz; Maciej Zmysłowski; Karolina Stefaniak; Grzegorz Oszkinis
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2016-04-27       Impact factor: 1.195

5.  Safety and efficacy of the StarClose vascular closure system following 8-Fr sheath placement for intra-aortic balloon pump: a single-center analysis of 42 consecutive patients.

Authors:  Guang Chu; Wenyi Yang; Guobing Zhang; Zhi Zhang; Shaowen Liu; Baogui Sun; Fang Wang
Journal:  Med Princ Pract       Date:  2014-04-23       Impact factor: 1.927

6.  Flip-over of blood vessel intima caused by vascular closure device: A case report.

Authors:  Li-Xia Sun; Xue-Song Yang; Da-Wei Zhang; Bo Zhao; Lian-Lian Li; Qi Zhang; Qing-Zhi Hao
Journal:  World J Clin Cases       Date:  2022-03-06       Impact factor: 1.337

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.