Cardio-respiratory exercise testing early after the use of the Angio-Seal system for arterial puncture site closure after coronary angioplasty.

Harald Rittger1, Martin Schmidt, Ole-Alexander Breithardt, Christian Mahnkopf, Johannes Brachmann, Anil-Martin Sinha.   

Abstract

AIMS: The vascular closure device (VCD) Angio-Seal is an easy-to-use system for the closure of arterial puncture sites after percutaneous coronary intervention (PCI), and allows for early mobilisation of the patient. However, little data are available about exercising early after the use of VCD's in PCI patients. METHODS AND
RESULTS: A total of 230 consecutive patients were screened. Of these, 45 (20%) were excluded due to the inability to perform exercise testing, or anatomical conditions which prevented the insertion of a VCD. The 185 remaining patients (139 male, mean age 68 ± 12 years) received Angio-Seal after PCI. After four hours, 30 patients (16%) showed a small local haematoma, 11 patients (6%) complained about minor -and one patient (0.5%) about strong- groin pain. There were no major bleeding complications, six pseudo-aneurysmata, and one arterio-venous fistula. Overall, nine patients (6%) showed moderate to severe groin problems. Patients without major complications underwent bicycle cardiopulmonary exercise testing the subsequent day. Exercise testing was performed up to 136 ± 60 W in 176 patients (94%). Maximum workload was 104 ± 33 W, peak oxygen consumption 17.6 ± 5.1 ml/min/kg, and oxygen consumption at the anaerobic threshold 15.4 ± 4.2 ml/min/kg. After exercise testing there were no cardiovascular complications noted.
CONCLUSIONS: In patients receiving VCD after PCI, exercise testing above the anaerobic threshold was feasible after Angio-Seal deployment in those patients with no complications after the use of the device.

Entities:  

Mesh:

Year:  2011        PMID: 21646067     DOI: 10.4244/EIJV7I2A39

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

1.  Comparison of Exo-Seal(®) and Angio-Seal (®) for arterial puncture site closure: A randomized, multicenter, single-blind trial.

Authors:  Johannes Ketterle; Harald Rittger; Inga Helmig; Lutz Klinghammer; Stefan Zimmermann; Wolfgang Hohenforst-Schmidt; Johannes Brachmann; Holger Nef; Stephan Achenbach; Christian Schlundt
Journal:  Herz       Date:  2015-06-13       Impact factor: 1.443

2.  Pituitrin use is associated with an increased risk of inguinal hematomas and pseudoaneurysms in patients undergoing femoral artery puncture.

Authors:  Fang Wang; Hua Su; Xiaoxia Wang; Qionghui Wu; Yong Zhou; Hangdi Xu; Ruifeng Zhang
Journal:  J Int Med Res       Date:  2019-05-23       Impact factor: 1.671

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.