Literature DB >> 21645695

On-line solid phase extraction of Ni and Pb using carbon nanotubes and modified carbon nanotubes coupled to ETAAS.

Marianela Savio1, Belén Parodi, Luis D Martinez, Patricia Smichowski, Raúl A Gil.   

Abstract

A study about the capabilities of three kinds of nanomaterials namely, carbon nanotubes (CNT), oxidized carbon nanotubes (ox-CNT) and l-alanine immobilized on carbon nanotubes (ala-CNT) to serve as sorbents for preconcentrating Ni and Pb using an on-line system coupled to electrothermal atomic absorption spectroscopy (ETAAS) technique, was accomplished. The solid phase extraction was performed in a conical minicolumn used as sorbent holder. After loading a fixed volume of the analytes, they were eluted with a discrete volume (50 μL) of nitric acid, placed directly into the platform of a L'Vov tube. After that, each analyte was determined individually. Ni and Pb retention was strongly influenced by pH but exhibiting different behaviors. The study demonstrated that the sorbent based on ox-CNTs was the one that exhibited the highest capacity and linearity for both analytes when compared with CNT or ala-CNT. The analytical performance was evaluated for the three sorbents to establish the best conditions regarding sensitivity, reproducibility and accuracy. The precision expressed as relative standard deviations (n=6) were 3.9 and 0.5% for Ni(2+) and Pb(2+), respectively The limit of detection (LOD), calculated as the concentration required to yield a net peak equal to three times the standard deviation of the background signal (3σ) was 30 and 10 ng L(-1) for Ni(2+) and Pb(2+) respectively. Alternatively, the limit of quantification (10σ) was calculated and resulted to be 0.79 and 0.07 μg L(-1) for Ni(2+) and Pb(2+) respectively. After optimization, the method that involved the use of ox-CNT associated to an on-line preconcentration was tested in samples of relevant environmental importance. Accuracy was evaluated analyzing a certified reference material namely, Municipal Sludge (QC MUNICIPAL SLUDGE A) and a reference sample of Lake Sediment (TRAP-LRM from IJS).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21645695     DOI: 10.1016/j.talanta.2011.03.054

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  p-Phenylenediamine-modified graphene oxide as a sorbent for solid-phase extraction of phenylurea herbicides, nitroimidazoles, chlorophenols, phenylurea insecticides and phthalates.

Authors:  Liying Guo; Lin Hao; Tian Gao; Chun Wang; Qiuhua Wu; Zhi Wang
Journal:  Mikrochim Acta       Date:  2019-06-22       Impact factor: 5.833

2.  Vortex assisted solid-phase extraction of lead(II) using orthorhombic nanosized Bi2WO6 as a sorbent.

Authors:  Neda Baghban; Erkan Yilmaz; Mustafa Soylak
Journal:  Mikrochim Acta       Date:  2017-12-07       Impact factor: 5.833

Review 3.  Carbon-based sorbents and their nanocomposites for the enrichment of heavy metal ions: a review.

Authors:  Beshare Hashemi; Shahabaldin Rezania
Journal:  Mikrochim Acta       Date:  2019-07-26       Impact factor: 5.833

4.  Super rapid removal of copper, cadmium and lead ions from water by NTA-silica gel.

Authors:  Yulian Li; Junyong He; Kaisheng Zhang; Tao Liu; Yi Hu; Xifan Chen; Chengming Wang; Xingjiu Huang; Lingtao Kong; Jinhuai Liu
Journal:  RSC Adv       Date:  2019-01-02       Impact factor: 4.036

  4 in total