Literature DB >> 21645680

Fast gradient high performance liquid chromatography method with UV detection for simultaneous determination of seven angiotensin converting enzyme inhibitors together with hydrochlorothiazide in pharmaceutical dosage forms and spiked human plasma and urine.

Fawzi Elsebaei1, Yan Zhu.   

Abstract

The development of a reversed phase liquid chromatographic method for the simultaneous determination of seven angiotensin converting enzyme (ACE) inhibitors; five drugs namely benazepril HCl (BZL), enalapril maleate (ENL), fosinopril sodium (FSP), lisinopril (LSP) and ramipril (RMP) and two metabolites captopril disulfide (CPD) and enalaprilat (ENT) together with hydrochlorothiazide (HCT) is described. The method can serve as a substitute for many published papers for the analysis of the targeted compounds with or without hydrochloothiazide in pharmaceutical formulations as well as in spiked human plasma and urine samples. The method utilizes a simple gradient procedure for the separation in a 11 min run time using acetonitrile aqueous ammonia buffer (pH 9) solution and an Extend RP-C18 (25 μm particle size, 4.6 mm×250 mm, Agilent) HPLC column. The effluent was monitored on a UV detector at 215 nm. The effect of pH, solvent strength and analysis time on the peak shape and quantification were carefully studied in order to optimize the method. Adopting the proposed procedure, the analytes produce well-shaped peaks with good linear relationship over the investigated concentration ranges. The limits of detection (LOD) and limits of quantification (LOQ) from standard drug solutions lie in the range of 17-64 and 56-212 ng mL(-1), respectively. Correlation coefficient values (r) higher than 0.997 were obtained for all the studied drugs in spiked human plasma and urine samples. The intra-day and inter-day precision of the method was evaluated with relative standard deviation values being satisfactory for their purposed analysis. The method was validated with respect to specificity, recovery, accuracy, precision and linearity.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21645680     DOI: 10.1016/j.talanta.2011.03.037

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Development and Validation of an HPLC Method Using an Experimental Design for Analysis of Amlodipine Besylate and Enalapril Maleate in a Fixed-dose Combination

Authors:  Diren Sarısaltık Yaşın; Alev Arslantürk Bingül; Alptuğ Karaküçük; Zeynep Şafak Teksin
Journal:  Turk J Pharm Sci       Date:  2021-06-18

2.  Fast and sensitive LC-MS/MS method for the simultaneous determination of lisinopril and hydrochlorothiazide in human plasma.

Authors:  Jaivik V Shah; Priyanka A Shah; Priya V Shah; Mallika Sanyal; Pranav S Shrivastav
Journal:  J Pharm Anal       Date:  2016-11-25

3.  Switch on fluorescence probe for the selective determination of lisinopril in pharmaceutical formulations: application to content uniformity testing.

Authors:  Fatma F Mohammed; Khalid M Badr El-Din; Sayed M Derayea
Journal:  RSC Adv       Date:  2018-05-01       Impact factor: 3.361

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.