Literature DB >> 21645665

Integrating amperometric detection with electrophoresis microchip devices for biochemical assays: recent developments.

M H Ghanim1, M Z Abdullah.   

Abstract

Recent advances in microfluidic systems, particularly in the Micro Total Analysis System (μTAS) or Lab On a Chip (LOC), drive the current analysis tools and equipment towards miniaturization, rapid at-line testing and mobility. The state-of-the-art microfluidic technology targets a wider range but smaller volumes of analytes, making the analytical procedure relatively easier and faster. This trend together with faster electronics and modern instrumentation systems will make real-time and in situ analysis a definite possibility. This review focuses on microchip capillary electrophoresis with amperometric detection (MCE-AD) for the detection of DNA and other electroactive analytes. The problems associated with the microchip design, in particular the choice of materials and the configuration of electrodes are discussed thoroughly and solutions are proposed. Significant developments in the related areas are also covered and reviewed critically.
Copyright © 2011 Elsevier B.V. All rights reserved.

Mesh:

Substances:

Year:  2011        PMID: 21645665     DOI: 10.1016/j.talanta.2011.04.069

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations.

Authors:  Diogenes Meneses; Dulan B Gunasekara; Pann Pichetsurnthorn; José A F da Silva; Fabiane C de Abreu; Susan M Lunte
Journal:  Electrophoresis       Date:  2014-11-14       Impact factor: 3.535

2.  Integration of a graphite/poly(methyl-methacrylate) composite electrode into a poly(methylmethacrylate) substrate for electrochemical detection in microchips.

Authors:  Anne Regel; Susan Lunte
Journal:  Electrophoresis       Date:  2013-07       Impact factor: 3.535

3.  Impact of Silanization Parameters and Antibody Immobilization Strategy on Binding Capacity of Photonic Ring Resonators.

Authors:  Nina Bjørk Arnfinnsdottir; Cole A Chapman; Ryan C Bailey; Astrid Aksnes; Bjørn Torger Stokke
Journal:  Sensors (Basel)       Date:  2020-06-02       Impact factor: 3.576

4.  Fabrication of an Amperometric Flow-Injection Microfluidic Biosensor Based on Laccase for In Situ Determination of Phenolic Compounds.

Authors:  Juan C Gonzalez-Rivera; Johann F Osma
Journal:  Biomed Res Int       Date:  2015-10-05       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.