Literature DB >> 21645663

Determination of parabens in shampoo using high performance liquid chromatography with amperometric detection on a boron-doped diamond electrode.

Isarita Martins1, Franciely Cristiani Carreira, Larissa S Canaes, Francisco Alberto de Souza Campos Junior, Letícia Maria da Silva Cruz, Susanne Rath.   

Abstract

Methylparaben (MePa), ethylparaben (EtPa) and propylparaben (PrPa) have been widely used, among others, as chemical preservatives in cosmetics, drugs and foods. As these compounds are linked with allergies, dermatitis and estrogenic properties, it is necessary to control the concentration of these substances in different matrices. The aim of this paper are: to evaluate the electrochemical behavior of parabens on the boron-doped diamond (BDD) electrode and the development of a chromatographic method, with electrochemical detection (HPLC-ED), for determination of parabens in shampoo. A BDD (8000 ppm) electrode was adapted in a thin layer mode analytical cell consisting of a stainless steel and a platinum wire as reference and auxiliary electrodes, respectively. Chromatographic separations were obtained with a reversed phase C8 analytical column and a mobile phase of 0.025 molL(-1) disodium phosphate, pH 7.0, and acetonitrile (40:60, v/v), delivered at a flow rate of 1.0 mL min(-1). Sample preparation was performed by solid phase extraction using C18 cartridges and acetonitrile for elution. Benzylparaben was employed as internal standard. The HPLC-ED method developed, using the BDD electrode, was validated for the determination of parabens in shampoos and presented adequate linearity (>0.999), in the range of 0.0125-0.500% (w/w), detectability 0.01% (w/w), precision (RSD of 2.3-9.8%) and accuracy (93.1-104.4%) and could be applied for routine quality control of shampoos containing MePa, EtPa and PrPa.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21645663     DOI: 10.1016/j.talanta.2011.04.047

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Serum analysis in women and in vitro skin assay for the assessment of exposure to parabens in antiperspirants.

Authors:  Isarita Martins; Mayara Lambert; Ana Flávia Souza Pereira; Henrique Dipe de Faria; Elizabete Campos de Lima; Gislaine Ribeiro Pereira
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-11       Impact factor: 4.223

  1 in total