Comparison of the effects of different electrocautery applications to peripheral nerves: an experimental study.

Ahmet Dagtekin1, Ulku Comelekoglu, Ozlen Bagdatoglu, Necat Yilmaz, Oykut Dagtekin, Aslihan Koseoglu, Yusuf Vayisoglu, Derya Karatas, Selma Korkutan, Emel Avci, Celal Bagdatoglu, Derya Talas.   

Abstract

BACKGROUND: This study was designed to investigate the effects of bipolar and mononopolar electrocauterization on peripheral nerve tissue. The comparison on the deleterious effects of the different cautery modalities and the importance of probe tip placement are evaluated using electrophysiological, electron microscopic and biochemical assessment parameters.
METHODS: Ninety-eight male Wistar albino rats, each weighing 250-275 g, were randomly divided into 14 groups. Each group consisted of seven animals. Monopolar and bipolar electrocautery were performed at 15 watts. The application was performed either directly on the nerve or 1 mm lateral to the longitudinal axis of the nerve for 'near the nerve groups', respectively.
RESULTS: The electrophysiological findings showed that the mean amplitudes were at the lowest value in the first day for all the groups. At the end of the 3rd week, we recognised that the electrophysiological recovery continued. Electron microscopic evaluation showed myelin disruption in all groups. Myelin disruption of healthy neurons was at the highest level in the 1st day of application in accordance with the electrophysiological findings. Biochemical evaluation revealed statistical significance between the control and the two of the 'near the nerve groups' (GIII and GV) for NO (nitrite and nitrate) serum level.
CONCLUSION: The data of the present study might suggest that electrocautery, independent of the type and form of application, may result in significant damage in histological and electrophysological basis. Although the relative proportions cannot be ascertained, the time course of recovery suggests that both axon and myelin damage have occurred. The probable electrocautery damage may be of substantial importance for the situation that the nerves are displaced by tumor masses or atypical neural traces.

Entities:  

Mesh:

Year:  2011        PMID: 21644008     DOI: 10.1007/s00701-011-1060-z

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  2 in total

1.  A prospective video-controlled study of genito-urinary disorders in 35 consecutive laparoscopic TMEs for rectal cancer.

Authors:  Andrea Costanzi; Luca Rigamonti; Giulio Maria Mari; Angelo Miranda; Jacopo Crippa; Valter Berardi; Dario Maggioni
Journal:  Surg Endosc       Date:  2014-10-11       Impact factor: 4.584

2.  Acute and subacute effects of the ultrasonic blade and electrosurgery on nerve physiology.

Authors:  Chaoyang Chen; Srinivasu Kallakuri; John M Cavanaugh; Duan Broughton; Jeffrey W Clymer
Journal:  Br J Neurosurg       Date:  2015-03-26       Impact factor: 1.596

  2 in total