Literature DB >> 21643045

Coherent anti-Stokes Raman scattering microscopy imaging with suppression of four-wave mixing in optical fibers.

Zhiyong Wang1, Liang Gao, Pengfei Luo, Yaliang Yang, Ahmad A Hammoudi, Kelvin K Wong, Stephen T C Wong.   

Abstract

We demonstrated an optical fiber delivered coherent anti-Stokes Raman scattering (CARS) microscopy imaging system with a polarization-based mechanism for suppression of four-wave mixing (FWM) signals in delivery fiber. Polarization maintaining fibers (PMF) were used as the delivery fiber to ensure stability of the state of polarization (SOP) of lasers. The pump and Stokes waves were coupled into PMFs at orthogonal SOPs along the slow and fast axes of PMFs, respectively, resulting in a significant reduction of FWM signals generated in the fiber. At the output end of PMFs, a dual-wavelength waveplate was used to realign the SOPs of the two waves into identical SOPs prior to their entrance into the CARS microscope. Therefore, it allows the pump and Stokes waves with identical SOPs to excite samples at highest excitation efficiency. Our experimental results showed that this polarization-based FWM-suppressing mechanism can dramatically reduce FWM signals generated in PMFs up to approximately 99%. Meanwhile, the PMF-delivered CARS microscopy system with this mechanism can still produce high-quality CARS images. Consequently, our PMF-delivered CARS microscopy imaging system with the polarization-based FWM-suppressing mechanism potentially offers a new strategy for building fiber-based CARS endoscopes with effective suppression of FWM background noises.

Mesh:

Year:  2011        PMID: 21643045     DOI: 10.1364/OE.19.007960

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  4 in total

1.  Multimodal nonlinear endo-microscopy probe design for high resolution, label-free intraoperative imaging.

Authors:  Xu Chen; Xiaoyun Xu; Daniel T McCormick; Kelvin Wong; Stephen T C Wong
Journal:  Biomed Opt Express       Date:  2015-06-03       Impact factor: 3.732

2.  Dual CARS and SHG image acquisition scheme that combines single central fiber and multimode fiber bundle to collect and differentiate backward and forward generated photons.

Authors:  Sheng Weng; Xu Chen; Xiaoyun Xu; Kelvin K Wong; Stephen T C Wong
Journal:  Biomed Opt Express       Date:  2016-05-16       Impact factor: 3.732

3.  Advances in engineering of high contrast CARS imaging endoscopes.

Authors:  Pascal Deladurantaye; Alex Paquet; Claude Paré; Huimin Zheng; Michel Doucet; David Gay; Michel Poirier; Jean-François Cormier; Ozzy Mermut; Brian C Wilson; Eric J Seibel
Journal:  Opt Express       Date:  2014-10-20       Impact factor: 3.894

4.  Combining deep learning and coherent anti-Stokes Raman scattering imaging for automated differential diagnosis of lung cancer.

Authors:  Sheng Weng; Xiaoyun Xu; Jiasong Li; Stephen T C Wong
Journal:  J Biomed Opt       Date:  2017-10       Impact factor: 3.170

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.