Literature DB >> 21642610

Prior epidural lidocaine alters the pharmacokinetics and drug effects of extended-release epidural morphine (DepoDur®) after cesarean delivery.

Lindsey Atkinson Ralls1, David R Drover, Claudia F Clavijo, Brendan Carvalho.   

Abstract

BACKGROUND: A potential physicochemical interaction between epidural local anesthetics and extended-release epidural morphine (EREM) could negate the sustained release. In this study, we sought to determine the pharmacokinetic and drug effects of prior epidural lidocaine administration on EREM.
METHODS: Thirty healthy women undergoing cesarean delivery were enrolled in this randomized study. Patients received 8 mg EREM 1 hour after either a combined spinal-epidural (intrathecal bupivacaine and fentanyl 20 μg with no epidural medication; group SE) or an epidural anesthetic (epidural 2% lidocaine with fentanyl 100 μg; group E). Maximal concentration (Cmax), time to Cmax (Tmax), and AUC(0-last) (area under the concentration-time curve until the last plasma concentration that was below the limit of quantitation) for morphine levels were determined from a plasma sample at 0, 5, 10, 15, and 30 minutes, and 1, 4, 8, 12, 24, 36, 48, and 72 hours. Drug effects including pain, analgesic use, and side effects were measured for 72 hours after cesarean delivery.
RESULTS: Epidural lidocaine administration (20-35 mL) 1 hour before epidural EREM administration increased the Cmax in group E (11.1 ± 4.9) compared with group SE (8.3 ± 7.1 ng/mL) (P = 0.038). There were no significant effects on Tmax and AUC(0-last) of venous morphine between the groups (P > 0.05). There was an increased incidence in vomiting, oxygen use, and hypotension in group E (patients who received lidocaine before EREM).
CONCLUSION: A large dose of epidural lidocaine 1 hour before EREM administration alters the pharmacokinetics and drug effects of EREM. Clinicians must apply caution when EREM is administered even 1 hour after an epidural lidocaine "top-up" for cesarean delivery.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21642610     DOI: 10.1213/ANE.0b013e318222f59c

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

Review 1.  Side Effects and Efficacy of Neuraxial Opioids in Pregnant Patients at Delivery: A Comprehensive Review.

Authors:  Sarah Armstrong; Roshan Fernando
Journal:  Drug Saf       Date:  2016-05       Impact factor: 5.606

2.  Cerebrospinal Fluid and Spinal Anesthesia Parameters in Healthy Individuals versus Opium-addict Patients during Lower Limb Surgery.

Authors:  Pooya Derakhshan; Farnad Imani; Seyed Alireza Seyed-Siamdoust; Sorour Garousi; Nasrin Nouri
Journal:  Addict Health       Date:  2020-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.