Literature DB >> 21641898

Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation.

M Ehlinger1, D Brinkert, J Besse, P Adam, Y Arlettaz, F Bonnomet.   

Abstract

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic distal femoral Less Invasive Stabilization System (LISS™) locking plate: e.g., a left distal femoral plate for femoral fracture on right-hip implant. This presents several advantages: minimally invasive surgery, the introduction of the plate being facilitated by the LISS™ ancillary; ease of locking, also thanks to the ancillary; and, above all, multiple proximal trochanteric fixation thanks to the form of this anatomic distal LISS™ plate, improving proximal bone fixation. The present technical note seeks to illustrate the interest of using a "reversed" plate, in terms of simplicity of fitting and quality of reduction and consolidation, while also specifying the associated limitations and tolerance.
Copyright © 2011 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21641898     DOI: 10.1016/j.otsr.2010.12.007

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  4 in total

1.  Minimally invasive surgery with locking plate for periprosthetic femoral fractures: technical note.

Authors:  Matthieu Ehlinger; Benjamin Scheibling; Michel Rahme; David Brinkert; Benoit Schenck; Antonio Di Marco; Philippe Adam; François Bonnomet
Journal:  Int Orthop       Date:  2015-08-08       Impact factor: 3.075

2.  Reversed distal femoral locking plate for failed proximal femoral nail with non-union of proximal femoral fractures.

Authors:  Raju Vaishya; Amit Kumar Agarwal; Nishint Gupta; Vipul Vijay
Journal:  Int Orthop       Date:  2015-10-09       Impact factor: 3.075

3.  Treatment of periprosthetic femoral fractures after femoral revision using a long stem.

Authors:  Youngwoo Kim; Chiaki Tanaka; Hiroshi Tada; Hiroshi Kanoe; Takaaki Shirai
Journal:  BMC Musculoskelet Disord       Date:  2015-05-10       Impact factor: 2.362

4.  Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures.

Authors:  Sampat S Dumbre Patil; Sachin S Karkamkar; Vaishali S Dumbre Patil; Shailesh S Patil; Abhijeet S Ranaware
Journal:  Indian J Orthop       Date:  2016 Jul-Aug       Impact factor: 1.251

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.