The status of bilirubin measurements in U.S. laboratories: why is accuracy elusive?

Stanley F Lo1, Basil T Doumas.   

Abstract

In 2003, the Chemistry Resource Committee of the College of American Pathologists introduced a new specimen in the Neonatal Bilirubin Survey. The specimen, consisting of human serum enriched with unconjugated bilirubin and thus resembling a clinical specimen, brought about an improvement in the accuracy of the measurement of bilirubin by laboratories participating in the Neonatal Bilirubin Survey. There was also an improvement in the specificity of methods measuring direct bilirubin. However, persisting inaccuracies and variability in laboratory performance have been traced to calibrators consisting of bovine serum spiked with unconjugated bilirubin and ditaurobilirubin; bovine serum causes underestimation of both bilirubins by 8 major chemical analyzers. To eradicate inaccuracy calibrators and Survey specimens should be made in human instead of bovine serum.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21641487     DOI: 10.1053/j.semperi.2011.02.008

Source DB:  PubMed          Journal:  Semin Perinatol        ISSN: 0146-0005            Impact factor:   3.300


  6 in total

1.  Natural history of early neonatal bilirubinemia: a global perspective.

Authors:  Michael Kaplan; M Jeffrey Maisels
Journal:  J Perinatol       Date:  2021-01-04       Impact factor: 2.521

2.  Accuracy of transcutaneous bilirubin measurement in preterm low-birth-weight neonates.

Authors:  Deepak Chawla; Suksham Jain; Gurjit Kaur; Vikas Sinhmar; Vishal Guglani
Journal:  Eur J Pediatr       Date:  2013-08-17       Impact factor: 3.183

Review 3.  Newborn Screening for Biliary Atresia: a Review of Current Methods.

Authors:  Tebyan Rabbani; Stephen L Guthery; Ryan Himes; Benjamin L Shneider; Sanjiv Harpavat
Journal:  Curr Gastroenterol Rep       Date:  2021-11-24

4.  Limitations and opportunities of whole blood bilirubin measurements by GEM premier 4000®.

Authors:  Li Wang; Arianne Y K Albert; Benjamin Jung; Keyvan Hadad; Martha E Lyon; Melanie Basso
Journal:  BMC Pediatr       Date:  2017-03-29       Impact factor: 2.125

5.  On-Site Monitoring of Postoperative Bile Leakage Using Bilirubin-Inducible Fluorescent Protein.

Authors:  Yoshiharu Kono; Takeaki Ishizawa; Norihiro Kokudo; Yugo Kuriki; Ryu J Iwatate; Mako Kamiya; Yasuteru Urano; Akiko Kumagai; Hiroshi Kurokawa; Atsushi Miyawaki; Kiyoshi Hasegawa
Journal:  World J Surg       Date:  2020-09-09       Impact factor: 3.352

6.  Transcutaneous bilirubin measurement in healthy Saudi term newborns.

Authors:  Saad A Alsaedi
Journal:  Saudi Med J       Date:  2016-02       Impact factor: 1.484

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.