Literature DB >> 21641450

Sequential injection analysis with electrochemical detection as a tool for economic and rapid evaluation of total antioxidant capacity.

S Chan-Eam1, S Teerasong, K Damwan, D Nacapricha, R Chaisuksant.   

Abstract

This work presents a new flow-based coupled electrochemical technique for evaluation of "total antioxidant capacity (TAC)". A sequential injection (SI) with amperometric detection was applied to the TAC analysis of commercial instant ginger infusion beverages using 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) assay. Besides having chromogenic properties, the ABTS reagent behaves as an electroactive species at the glassy carbon electrode in phosphate buffer pH 7.0, the decrease of the cathodic current signal of the ABTS(+) radical after reaction with antioxidants can be monitored. The SI system, furnished with an in-house electrochemical detection cell (ECD), was optimized with respect to the applied potential, sample and reagent volume, and flow rate to the detector. Gallic acid was used as the standard antioxidant and the capacity was reported as gallic acid equivalent (GAE) unit. TAC measurements of ginger infusions at the optimum condition were performed using the proposed technique and also with the classical batch spectrophotometric ABTS assay. TAC values obtained from our method and the standard method are in good agreement (r(2)=0.956). The SI-amperometric technique provided satisfactory precision (4.11% RSD) with rapid sample throughput (40 samples h(-1)). Also using this method, the consumption of the expensive ABTS reagent was greatly reduced.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21641450     DOI: 10.1016/j.talanta.2011.02.043

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Antioxidant Capacity Determination in Plants and Plant-Derived Products: A Review.

Authors:  Aurelia Magdalena Pisoschi; Aneta Pop; Carmen Cimpeanu; Gabriel Predoi
Journal:  Oxid Med Cell Longev       Date:  2016-12-04       Impact factor: 6.543

2.  A novel flow injection amperometric method for sensitive determination of total antioxidant capacity at cupric-neocuproine complex modified MWCNT glassy carbon electrode.

Authors:  Selen Ayaz; Ayşem Üzer; Yusuf Dilgin; Reşat Apak
Journal:  Mikrochim Acta       Date:  2022-03-31       Impact factor: 5.833

3.  Electrochemical Flow-ELISA for Rapid and Sensitive Determination of Microcystin-LR Using Automated Sequential Injection System.

Authors:  Lesedi Lebogang; Jongjit Jantra; Martin Hedström; Bo Mattiasson
Journal:  Sensors (Basel)       Date:  2017-07-16       Impact factor: 3.576

Review 4.  Analytical Methods Used in Determining Antioxidant Activity: A Review.

Authors:  Irina Georgiana Munteanu; Constantin Apetrei
Journal:  Int J Mol Sci       Date:  2021-03-25       Impact factor: 5.923

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.