Literature DB >> 21641449

Simultaneous determination of some food additives in soft drinks and other liquid foods by flow injection on-line dialysis coupled to high performance liquid chromatography.

Orawan Kritsunankul1, Jaroon Jakmunee.   

Abstract

Flow injection on-line dialysis was developed for sample pretreatment prior to the simultaneous determination of some food additives by high performance liquid chromatography (FID-HPLC). A liquid sample or mixed standard solution (900 μL) was injected into a donor stream (5%, w/v, sucrose) of FID system and was pushed further through a dialysis cell, while an acceptor solution (0.025 mol L(-1) phosphate buffer, pH 3.75) was held in the opposite side of the dialysis membrane. The dialysate was then flowed to an injection loop of the HPLC valve, where it was further injected into the HPLC system and analyzed under isocratic reverse-phase HPLC conditions and UV detection (230 nm). The order of elution of five food additives was acesulfame-K, saccharin, caffeine, benzoic acid and sorbic acid, respectively, with the analysis time of 14 min. On-line dialysis and HPLC analysis could be performed in parallel, providing sample throughput of 4.3h(-1). Dialysis efficiencies of five food additives were in ranges of 5-11%. Linear calibration graphs were in ranges of 10-100 mg L(-1) for acesulfame-K and saccharin, 10-250 mg L(-1) for benzoic acid and 10-500 mg L(-1) for caffeine and sorbic acid. Good precisions (RSD<5%) for all the additives were obtained. The proposed system was applied to soft drink and other liquid food samples. Acceptable percentage recoveries could be obtained by appropriate dilution of the sample before injecting into the system. The developed system has advantages of high degrees of automation for sample pretreatment, i.e., on-line sample separation and dilution and low consumption of chemicals and materials. Crown
Copyright © 2011. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21641449     DOI: 10.1016/j.talanta.2011.02.045

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Development of a Sequential Injection Analysis System for the Determination of Saccharin.

Authors:  Budi Wibowotomo; Jong-Bang Eun; Jong Il Rhee
Journal:  Sensors (Basel)       Date:  2017-12-12       Impact factor: 3.576

2.  Flow-based systems for rapid and high-precision enzyme kinetics studies.

Authors:  Supaporn Kradtap Hartwell; Kate Grudpan
Journal:  J Anal Methods Chem       Date:  2012-04-22       Impact factor: 2.193

Review 3.  Analytical Methods for Determination of Non-Nutritive Sweeteners in Foodstuffs.

Authors:  Viki Oktavirina; Nadhila B Prabawati; Rohmah Nur Fathimah; Miguel Palma; Kiki Adi Kurnia; Noviyan Darmawan; Brian Yulianto; Widiastuti Setyaningsih
Journal:  Molecules       Date:  2021-05-24       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.