Lab on valve-multisyringe flow injection system (LOV-MSFIA) for fully automated uranium determination in environmental samples.

Jessica Avivar1, Laura Ferrer, Montserrat Casas, Víctor Cerdà.   

Abstract

The hyphenation of lab-on-valve (LOV) and multisyringe flow analysis (MSFIA), coupled to a long path length liquid waveguide capillary cell (LWCC), allows the spectrophotometric determination of uranium in different types of environmental sample matrices, without any manual pre-treatment, and achieving high selectivity and sensitivity levels. On-line separation and preconcentration of uranium is carried out by means of UTEVA resin. The potential of the LOV-MSFIA makes possible the fully automation of the system by the in-line regeneration of the column. After elution, uranium(VI) is spectrophotometrically detected after reaction with arsenazo-III. The determination of levels of uranium present in environmental samples is required in order to establish an environmental control. Thus, we propose a rapid, cheap and fully automated method to determine uranium(VI) in environmental samples. The limit of detection reached is 1.9 ηg of uranium and depending on the preconcentrated volume; it results in ppt levels (10.3 ηg L(-1)). Different water sample matrices (seawater, well water, freshwater, tap water and mineral water) and a phosphogypsum sample (with natural uranium content) were satisfactorily analyzed.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Year:  2010        PMID: 21641430     DOI: 10.1016/j.talanta.2010.12.018

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  A Customizable Flow Injection System for Automated, High Throughput, and Time Sensitive Ion Mobility Spectrometry and Mass Spectrometry Measurements.

Authors:  Daniel J Orton; Malak M Tfaily; Ronald J Moore; Brian L LaMarche; Xueyun Zheng; Thomas L Fillmore; Rosalie K Chu; Karl K Weitz; Matthew E Monroe; Ryan T Kelly; Richard D Smith; Erin S Baker
Journal:  Anal Chem       Date:  2017-12-13       Impact factor: 6.986

2.  A LabVIEW®-based software for the control of the AUTORAD platform: a fully automated multisequential flow injection analysis Lab-on-Valve (MSFIA-LOV) system for radiochemical analysis.

Authors:  Donato Barbesi; Víctor Vicente Vilas; Sylvain Millet; Miguel Sandow; Jean-Yves Colle; Laura Aldave de Las Heras
Journal:  J Radioanal Nucl Chem       Date:  2017-05-22       Impact factor: 1.371

Review 3.  Dynamic Flow Approaches for Automated Radiochemical Analysis in Environmental, Nuclear and Medical Applications.

Authors:  Jixin Qiao
Journal:  Molecules       Date:  2020-03-24       Impact factor: 4.411

  3 in total