Literature DB >> 21639197

Amperometric sensors for simultaneous superoxide and hydrogen peroxide detection.

V Lvovich1, A Scheeline.   

Abstract

A two-channel sensor capable of almost instantaneous simultaneous detection of superoxide radical and hydrogen peroxide in the concentration range 10(-)(7)-10(-)(4) M is very important for understanding of a number of rapid kinetics processes. A glassy carbon working microelectrode covered by an electrodeposited polypyrrole/horseradish peroxidase (PPy/HRP) membrane was employed as a H(2)O(2) sensor. Another glassy carbon microelectrode covered by a composite membrane of an inside layer of PPy/HRP and an outside layer of superoxide dismutase was employed as a working electrode for superoxide detection. These two working electrodes with Pt counter and tungsten oxide (WO(3)) reference electrodes were contained in one 6 mm diameter Teflon cylinder. Simultaneous measurements were performed at a potential of -60 mV (vs WO(3) reference, pH 5.1). Additional sensor characterization was performed for pH 5.1-9.0. Superoxide sensor behavior as a function of membrane deposition conditions and coating time is reported. Sensors' mutual influence, selectivity, response times, linearity, stability, and sensitivity for hydrogen peroxide and superoxide are presented and discussed. A mathematical model of sensors' responses is proposed, with model calculation corresponding to experiment within 10%.

Entities:  

Year:  1997        PMID: 21639197     DOI: 10.1021/ac9606261

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Effects of angiotensin receptor blockers on endothelial nitric oxide release: the role of eNOS variants.

Authors:  R Preston Mason; Robert F Jacob; Ruslan Kubant; Adam Jacoby; Febee Louka; J Jose Corbalan; Tadeusz Malinski
Journal:  Br J Clin Pharmacol       Date:  2012-07       Impact factor: 4.335

2.  Indirect detection of superoxide in RAW 264.7 macrophage cells using microchip electrophoresis coupled to laser-induced fluorescence.

Authors:  Richard P S de Campos; Joseph M Siegel; Claudia G Fresta; Giuseppe Caruso; José A F da Silva; Susan M Lunte
Journal:  Anal Bioanal Chem       Date:  2015-07-10       Impact factor: 4.142

3.  DNA-induced synthesis of biomimetic enzyme for sensitive detection of superoxide anions released from live cell.

Authors:  Ailing Ding; Bin Wang; Xiaoqing Ma; Jianglin Diao; Jiushang Zheng; Jiucun Chen; Changming Li
Journal:  RSC Adv       Date:  2018-04-03       Impact factor: 4.036

4.  Synergistic effect of amlodipine and atorvastatin in reversing LDL-induced endothelial dysfunction.

Authors:  R Preston Mason; Ruslan Kubant; Gehan Heeba; Robert F Jacob; Charles A Day; Yehudi S Medlin; Philipp Funovics; Tadeusz Malinski
Journal:  Pharm Res       Date:  2007-12-18       Impact factor: 4.200

5.  Spatiotemporal intracellular nitric oxide signaling captured using internalized, near-infrared fluorescent carbon nanotube nanosensors.

Authors:  Zachary W Ulissi; Fatih Sen; Xun Gong; Selda Sen; Nicole Iverson; Ardemis A Boghossian; Luiz C Godoy; Gerald N Wogan; Debabrata Mukhopadhyay; Michael S Strano
Journal:  Nano Lett       Date:  2014-07-30       Impact factor: 11.189

6.  Mechanistic Study of the Conversion of Superoxide to Oxygen and Hydrogen Peroxide in Carbon Nanoparticles.

Authors:  Almaz S Jalilov; Chenhao Zhang; Errol L G Samuel; William K A Sikkema; Gang Wu; Vladimir Berka; Thomas A Kent; Ah-Lim Tsai; James M Tour
Journal:  ACS Appl Mater Interfaces       Date:  2016-06-10       Impact factor: 9.229

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.