Literature DB >> 21639090

Magneto-controlled graphene immunosensing platform for simultaneous multiplexed electrochemical immunoassay using distinguishable signal tags.

Juan Tang1, Dianping Tang, Reinhard Niessner, Guonan Chen, Dietmar Knopp.   

Abstract

A novel flow-through multiplexed immunoassay protocol for simultaneous electrochemical determination of carcinoembryonic (CEA) and alpha-fetoprotein (AFP) in biological fluids was designed using biofunctionalized magnetic graphene nanosheets (MGO) as immunosensing probes and multifunctional nanogold hollow microspheres (GHS) as distinguishable signal tags. The probes were fabricated by means of co-immobilization of primary anti-CEA (Ab(1)) and anti-AFP (Ab(2)) antibodies on the Fe(3)O(4) nanoparticle-coated graphene nanosheets (MGO-Ab(1,2)). The reverse-micelle method was used for the synthesis of distinguishable signal tags by encapsulation of horseradish peroxide (HRP)-thionine and HRP-ferrocene into nanogold hollow microspheres, respectively, which were utilized as labels of the corresponding GHS-Ab(1) and GHS-Ab(2). A sandwich-type immunoassay format was employed for the online detection of CEA and AFP by coupling a flow-through detection cell with an external magnet. The assay was based on the catalytic reduction of H(2)O(2) at the various peak potentials in the presence of the corresponding mediators. Experimental results revealed that the multiplexed electrochemical immunoassay enabled the simultaneous monitoring of AFP and CEA in a single run with wide working ranges of 0.01-200 ng mL(-1) for AFP and 0.01-80 ng mL(-1) for CEA. The detection limits (LODs) for both analytes at 1.0 pg mL(-1) (at 3s(B)) were very low. No obvious nonspecific adsorption and cross-talk were observed during a series of analyses to detect target analytes. Intraassay and interassay coefficients of variation were <10%. Importantly, the methodology was evaluated for the analysis of clinical serum specimens, receiving a good correlation between the flow-through multiplexed electrochemical immunoassay and an electrochemiluminescence method as a reference.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21639090     DOI: 10.1021/ac200969w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Multiplex Immunosensor Arrays for Electrochemical Detection of Cancer Biomarker Proteins.

Authors:  Bernard S Munge; Thomas Stracensky; Kathleen Gamez; Dimitri DiBiase; James F Rusling
Journal:  Electroanalysis       Date:  2016-06-07       Impact factor: 3.223

2.  Silver Nanocubes as Electrochemical Labels for Bioassays.

Authors:  Yi Peng; Charlie Rabin; Charuksha T Walgama; Nicole E Pollok; Leilani Smith; Ian Richards; Richard M Crooks
Journal:  ACS Sens       Date:  2021-01-13       Impact factor: 7.711

3.  A new method to amplify colorimetric signals of paper-based nanobiosensors for simple and sensitive pancreatic cancer biomarker detection.

Authors:  K Sudhakara Prasad; Yousef Abugalyon; Chunqiang Li; Feng Xu; XiuJun Li
Journal:  Analyst       Date:  2020-06-26       Impact factor: 4.616

Review 4.  Electrochemistry of nonconjugated proteins and glycoproteins. Toward sensors for biomedicine and glycomics.

Authors:  Emil Paleček; Jan Tkáč; Martin Bartošík; Tomáš Bertók; Veronika Ostatná; Jan Paleček
Journal:  Chem Rev       Date:  2015-02-09       Impact factor: 60.622

5.  Magnetic bead-based colorimetric immunoassay for aflatoxin B1 using gold nanoparticles.

Authors:  Xu Wang; Reinhard Niessner; Dietmar Knopp
Journal:  Sensors (Basel)       Date:  2014-11-14       Impact factor: 3.576

Review 6.  Multiplexed Point-of-Care Testing - xPOCT.

Authors:  Can Dincer; Richard Bruch; André Kling; Petra S Dittrich; Gerald A Urban
Journal:  Trends Biotechnol       Date:  2017-04-26       Impact factor: 19.536

Review 7.  Multiplexed Electrochemical Immunosensors for Clinical Biomarkers.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2017-04-27       Impact factor: 3.576

8.  Aptasensor for multiplex detection of antibiotics based on FRET strategy combined with aptamer/graphene oxide complex.

Authors:  Hyungjun Youn; Kwanghyun Lee; Jin Her; Jinseong Jeon; Jihyun Mok; Jae-In So; Sangeon Shin; Changill Ban
Journal:  Sci Rep       Date:  2019-05-21       Impact factor: 4.379

9.  A SPR biosensor based on signal amplification using antibody-QD conjugates for quantitative determination of multiple tumor markers.

Authors:  Huan Wang; Xiaomei Wang; Jue Wang; Weiling Fu; Chunyan Yao
Journal:  Sci Rep       Date:  2016-09-12       Impact factor: 4.379

Review 10.  Application of Microfluidics in Immunoassay: Recent Advancements.

Authors:  Yuxing Shi; Peng Ye; Kuojun Yang; Jie Meng; Jiuchuan Guo; Zhixiang Pan; Qiaoge Bayin; Wenhao Zhao
Journal:  J Healthc Eng       Date:  2021-07-15       Impact factor: 2.682

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.