Literature DB >> 21638147

Efficacy and safety of two different n-butyl-2-cyanoacrylates for the embolization of varicoceles: a prospective, randomized, blinded study.

Peter Vanlangenhove1, Katrien De Keukeleire, Karel Everaert, Georges Van Maele, Luc Defreyne.   

Abstract

PURPOSE: This was a prospective, randomized, blinded comparative study of the efficacy and safety of two different n-butyl-2-cyanoacrylates (NBCAs) for embolization of varicoceles.
METHODS: A total of 112 insufficient spermatic veins (left-sided, n=84; right-sided, n=28) that were diagnosed in 83 adult males were prospectively randomized for blinded embolization with NBCA (n=54; Histoacryl, Braun, Germany) or NBCA-MS (n=58; Glubran2, General Enterprise Marketing, Viareggio, Lucca, Italy). Handling, embolic efficacy, and safety of both NBCAs were compared according the fulfillment of a standardized embolization plan, the occlusive effect on the spermatic vein, and the sticking to the microcatheter. Statistical analysis was performed with the Mann-Whitney U test and the Fisher's exact test.
RESULTS: Patients of both study arms were comparable for age and clinical indication. Spermatic vein characteristics were comparable for varicocele classification and embolization side. Both NBCAs were equally efficient in occluding the spermatic vein and blocking reflux (NBCA, n=54/54, 100% vs. NBCA-MS, n=54/57, 94.7%; P=0.244). The embolization plan could be accomplished in an equal number of veins for both groups (NBCA, n=45/54, 83.3% vs. NBCA-MS, n=41/58, 70.7%; P=0.124). Adhesiveness of the glue to the microcatheter was the same in both NBCA groups (NBCA, n=25/54, 46.3% vs. NBCA-MS, n=29/58, 50%; P=0.71). No glue-related complications were noted.
CONCLUSIONS: NBCA and NBCA-MS are equally efficient and safe glues for embolization of varicoceles.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21638147     DOI: 10.1007/s00270-011-0188-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  5 in total

1.  Comparison of three different embolic materials for varicocele embolization: retrospective study of tolerance, radiation and recurrence rate.

Authors:  Nicolas Favard; Morgan Moulin; Patricia Fauque; Aurélie Bertaut; Sylvain Favelier; Louis Estivalet; Frédéric Michel; Luc Cormier; Paul Sagot; Romaric Loffroy
Journal:  Quant Imaging Med Surg       Date:  2015-12

2.  Urticarial reaction following endovascular embolization of an orbital arteriovenous malformation (AVM) with n-butyl cyanoacrylate (nBCA) glue.

Authors:  Kunal R Sinha; Gary Duckwiler; Daniel B Rootman
Journal:  Interv Neuroradiol       Date:  2017-09-11       Impact factor: 1.610

3.  Endovascular embolization of varicoceles using n-butyl cyanoacrylate (NBCA) glue.

Authors:  Radosław Pietura; Michał Toborek; Aneta Dudek; Agata Boćkowska; Joanna Janicka; Paweł Piekarski
Journal:  Pol J Radiol       Date:  2013-04

4.  Surgical or radiological treatment for varicoceles in subfertile men.

Authors:  Emma Persad; Clare Aa O'Loughlin; Simi Kaur; Gernot Wagner; Nina Matyas; Melanie Rosalia Hassler-Di Fratta; Barbara Nussbaumer-Streit
Journal:  Cochrane Database Syst Rev       Date:  2021-04-23

5.  Contribution to the Pathophysiology and Treatment of Varicoceles.

Authors:  Peter Vanlangenhove
Journal:  J Belg Soc Radiol       Date:  2018-02-09       Impact factor: 1.894

  5 in total