Literature DB >> 21636091

Optimization of the derivatization reaction and the solid-phase microextraction conditions using a D-optimal design and three-way calibration in the determination of non-steroidal anti-inflammatory drugs in bovine milk by gas chromatography-mass spectrometry.

David Arroyo1, M Cruz Ortiz, Luis A Sarabia.   

Abstract

An experimental design optimization is reported of an analytical procedure used in the simultaneous determination of seven non-steroidal anti-inflammatory drugs (NSAIDs) in bovine milk by gas chromatography with mass spectrometry detection (GC-MS). This analytical procedure involves a solid-phase microextraction (SPME) step and an aqueous derivatization procedure of the NSAIDs to ethyl esters in bovine milk. The following NSAIDs are studied: ibuprofen (IBP), naproxen (NPX), ketoprofen (KPF), diclofenac (DCF), flufenamic acid (FLF), tolfenamic acid (TLF) and meclofenamic acid (MCL). Three kinds of SPME fibers - polyacrylate (PA), polydimethylsiloxane/divinylbenzene (PDMS/DVB) and polydimethylsiloxane (PDMS) - are compared to identify the most suitable one for the extraction process, on the basis of two steps: to determine the equilibrium time of each fiber and to select the fiber that provides the best figures-of-merit values calculated with three-way PARAFAC-based calibration models at the equilibrium time. The best results were obtained with the PDMS fiber. Subsequently, 8 experimental factors (related to the derivatization reaction and the SPME) were optimized by means of a D-optimal design that involves only 14 rather than 512 experiments in the complete factorial design. The responses used in the design are the sample mode loadings of the PARAFAC decomposition which are related to the quantity of each NSAID that is extracted in the experiment. Owing to the fact that each analyte is unequivocally identified in the PARAFAC decomposition, a calibration model is not needed for each experimental condition. The procedure fulfils the performance requirements for a confirmatory method established in European Commission Decision 2002/657/EC.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21636091     DOI: 10.1016/j.chroma.2011.05.010

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Method for quantifying NSAIDs and clofibric acid in aqueous samples, lumpfish (Cyclopterus lumpus) roe, and zebrafish (Danio rerio) eleutheroembryos and evaluation of their bioconcentration in zebrafish eleutheroembryos.

Authors:  N Molina-Fernandez; C Perez-Conde; S Rainieri; J Sanz-Landaluze
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-11       Impact factor: 4.223

Review 2.  Optimizing Mass Spectrometry Analyses: A Tailored Review on the Utility of Design of Experiments.

Authors:  Elizabeth S Hecht; Ann L Oberg; David C Muddiman
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-07       Impact factor: 3.109

3.  New sporopollenin-based β-cyclodextrin functionalized magnetic hybrid adsorbent for magnetic solid-phase extraction of nonsteroidal anti-inflammatory drugs from water samples.

Authors:  Syed Fariq Fathullah Syed Yaacob; Muhammad Afzal Kamboh; Wan Aini Wan Ibrahim; Sharifah Mohamad
Journal:  R Soc Open Sci       Date:  2018-07-18       Impact factor: 2.963

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.