Literature DB >> 21631629

Fracture resistance of ceramic veneers with different preparation designs.

Burçin Akoğlu1, Deniz Gemalmaz.   

Abstract

PURPOSE: The purpose of this study was to examine the fracture load of ceramic veneers with different preparation designs.
MATERIALS AND METHODS: Seventy-five extracted, intact, human maxillary central incisors were prepared according to five preparation designs (P) (n: 15) as follows: (1) P2e: 2-mm incisal reduction, preparation entirely in enamel; (2) P4e: 4-mm incisal reduction, preparation entirely in enamel; (3) P2d: 2-mm incisal reduction, preparation entirely in dentin; (4) P4d: 4-mm incisal reduction, preparation entirely in dentin; and (6) Pc: Unrestored, intact teeth as control. All preparations had a butt joint incisal finish line, rounded internal line angles, and cervical finish lines 1 mm above the cementoenamel junction. Ceramic veneers were fabricated with IPS Empress (Ivoclar Vivadent AG, Schaan, Liechtenstein) and cemented with Syntac Classic Adhesive system and Variolink II (Ivoclar) resin cement. Veneers were loaded until fracture at a 90° angle to the lingual surface of the test tooth following the thermocycling process (5° to 55°, 3500 times). Statistical analyses were performed using analysis of variance (ANOVA) and Tukey's Multiple Range Test.
RESULTS: The mean fracture loads (SD) were (in N) as follows: (1) P2e: 262 (63); (2) P4e: 189 (40); (3) P2d: 239 (53); (4) P4d: 162 (36); and (5) Pc: 277 (66). The amount of incisal reduction exhibited a significant influence on fracture resistance regardless of the preparation depth (p < 0.05).
CONCLUSIONS: Ceramic veneers with preparation designs entirely on dentin with 4-mm incisal reduction yielded lower fracture loads than those prepared with 2-mm incisal reduction. Veneers with 2-mm incisal reduction exhibited fracture resistance similar to that of intact teeth for preparation designs supplied on both enamel and dentin.
© 2011 by the American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21631629     DOI: 10.1111/j.1532-849X.2011.00728.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  3 in total

Review 1.  Minimally invasive veneers: current state of the art.

Authors:  Burçin Akoğlu Vanlıoğlu; Yasemin Kulak-Özkan
Journal:  Clin Cosmet Investig Dent       Date:  2014-11-28

2.  An in-vitro comparison of fracture resistance of three CAD/CAM Ceramic materials for fabricating Veneer.

Authors:  Abdul Rahman Mohammed Saleh; Mena Al-Ani; Tuqa ALRawi; Ghufran Al-Edressi
Journal:  Saudi Dent J       Date:  2020-03-31

3.  Evaluation of fracture resistance of ceramic veneers with different preparation designs and loading conditions: An in vitro study.

Authors:  Aman Arora; Viram Upadhyaya; Sheen J Arora; Prachi Jain; Avneet Yadav
Journal:  J Indian Prosthodont Soc       Date:  2017 Oct-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.