| Literature DB >> 21625743 |
José Ferreira Costa1, Walter Luiz Siqueira, Alessandro Dourado Loguercio, Alessandra Reis, Elizabeth de Oliveira, Cláudia Maria Coelho Alves, José Roberto de Oliveira Bauer, Rosa Helena Miranda Grande.
Abstract
OBJECTIVES: To determine the pH over a period of 168 h and the ionic silver content in various concentrations and post-preparation times of aqueous silver nitrate solutions. Also, the possible effects of these factors on microleakage test in adhesive/resin restorations in primary and permanent teeth were evaluated.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21625743 PMCID: PMC4234339 DOI: 10.1590/s1678-77572011000300014
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Material and sequence used in adhesive procedures
| Filler: 48% weight (Ba-Al silicate borum, pyrolytic silicone, disodium silicate hexafluoride) | |||
| Filler: 15% weight (Ba-Al silicate borum, pyrolytic silicone, disodium silicate hexafluoride) | |||
| Etching Agent (Kerr SDS, Orange, CA, USA) 301194 | Gel | 37.5% phosphoric acid |
Sequence of application: a) acid etching of cavity (15 s enamel + 15 s dentin); b) wash with water (30 s); c) vigorous drying with air; d) wet cavity with water (2 µl); e) apply primer rubbing the surface (15 s) and apply light jet of air (5 s); f) uniform application of bond FL in a single layer and light-activation 600mW/cm2 (30 s); g) apply self-etching primer SE rubbing the surface lightly (15 s) and apply light jet of air (5 s); h) apply first layer of bond SE rubbing lightly (15 s) and light jet of air (3 s); i) apply second layer of bond SE and light jet of air (3 s) and light-activation 600mW/cm2 (20 s)
Figure 2Means and standard deviations of pH according to the post-preparation times of solutions
Figure 3Distribution of the amount of ionic silver in the solutions according to the post-preparation times and concentrations
Mean values and standard deviations (mm) of tracer penetration in permanent teeth regarding adhesive systems according to concentration and post preparation time of solutions as well as statistical significance *
| Mean ± standard deviation | 1.6±0.4a | 1.9±0.6b | 1.2±0.8a | 2.2±0.4b | 1.6±0.4a | 2.2±0.4b | 1.6±0.3a | 2.2±0.5b |
Values with same letter are not significantly different (p>0.05). FL= Optibond FL; SE= Optibond SOLO Plus SE
Mean values (mm) ± standard deviations (SD) of tracer penetration in deciduous teeth regarding adhesive systems according to concentration of solutions, as well as, statistical significance *
| Mean ± SD | 0.038±0.08a | 0.348±0.40b | 0.025±0.04a | 0.428±0.42b |
Values with same letter are not significantly different (p>0.05). FL= Optibond FL; SE= Optibond SOLO Plus SE