Comparison of ultrasound-guided biopsy technique for thyroid nodules with respect to adequacy of cytological material.

Emad Kandil1, Mohamed Abdel Khalek, Haytham Alabbas, Krzysztof Moroz, Tareq Islam, Paul Friedlander, Bernard M Jaffe.   

Abstract

BACKGROUND: Ultrasound-guided fine-needle aspiration cytology (FNAC) sampling of the thyroid represents a standard diagnostic procedure in the evaluation of thyroid nodules. The specimen can be acquired using either of two different techniques. In the first, the short axis is used with observation only of the tip of the needle whilst in the nodule. In the second technique, the long axis is used with the observation of the entire length of the needle. The decision to sample utilizing either technique was done randomly. This study is a retrospective review performed to compare these two techniques with regard to specimen adequacy.
METHODS: Ultrasound-guided FNACs were performed in 80 thyroid nodules between May 2008 and February 2009. One physician acquired the cytology specimens using one of these two methods after localization. Data on the type of technique and its diagnostic accuracy were collected.
RESULTS: Forty-nine of 80 thyroid nodules were sampled using the long-axis technique. The overall and deep-lesion diagnostic adequacies of specimens were significantly higher using this technique (93.9 and 95.1%, respectively, p < 0.01) than the short-axis technique. When comparing the long and short axes for superficial lesions, there was no significant difference in adequacy of the samples (p = 0.92).
CONCLUSIONS: This is the first study to compare long- and short-axis techniques with regard to specimen adequacy for thyroid nodules. The long-axis technique decreased the rate of inadequate material and provided more accurate cytological evaluation for deeper lesions.
Copyright © 2011 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2011        PMID: 21625193     DOI: 10.1159/000323005

Source DB:  PubMed          Journal:  ORL J Otorhinolaryngol Relat Spec        ISSN: 0301-1569            Impact factor:   1.538


  3 in total

Review 1.  Ultrasound-guided fine needle aspiration of thyroid nodules: a consensus statement by the korean society of thyroid radiology.

Authors:  Young Hen Lee; Jung Hwan Baek; So Lyung Jung; Jin Young Kwak; Ji-hoon Kim; Jung Hee Shin
Journal:  Korean J Radiol       Date:  2015-02-27       Impact factor: 3.500

2.  Battle of the axes: simulation-based assessment of fine needle aspiration biopsies for thyroid nodules.

Authors:  Shireen Samargandy; Justine Philteos; Mirko Manojlovic Kolarski; Jason Xu; Eric Monteiro; Allan Vescan
Journal:  J Otolaryngol Head Neck Surg       Date:  2022-08-19

3.  High-Score US-Suspicious Subcentimeter Thyroid Nodules: What Factors Affect Adequate Sampling of US-Guided Fine-Needle Aspiration Biopsy?

Authors:  Yang Li; Jin Hong Yu; Ping Jie Du; Yu Xie; Sushant Kumar Das; Bing Li; Chuan Zhang
Journal:  Int J Endocrinol       Date:  2020-04-21       Impact factor: 3.257

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.