Literature DB >> 21624678

Bacterial adherence to high--tensile strength sutures.

Brendan D Masini1, Daniel J Stinner, Scott M Waterman, Joseph C Wenke.   

Abstract

PURPOSE: The purpose of this study was to evaluate the bacterial adherence to high--tensile strength suture materials using a bioluminescent in vitro model.
METHODS: Eleven strands each of No. 2 MaxBraid (Arthrotek [Biomet], Warsaw, IN), FiberWire (Arthrex, Naples, FL), Ethibond (Ethicon, Somerville, NJ), Orthocord (DePuy Mitek, Raynham, MA), and silk (Ethicon) sutures were immersed in a broth of bioluminescent Staphylococcus aureus, which is genetically engineered to emit photons. After 12 hours in the broth, the suture strands were individually irrigated with 10 mL of low-pressure normal saline solution and imaged with a photon-capturing camera system that yields a total photon count that correlates directly with residual bacterial counts.
RESULTS: MaxBraid had the greatest adherence, followed by FiberWire, Ethibond, Orthocord, and silk. Orthocord had only 25% of the bacterial adherence of MaxBraid (P < .001). Ethibond and FiberWire had 53% (P < .001) and 75% (P = .003) of the adherence of MaxBraid, respectively. Differences between each suture were also statistically significant, with Ethibond and Orthocord having 71% (P = .007) and 33% (P < .001) of the adherence of FiberWire, respectively, and Orthocord having 47% (P < .001) of the adherence of Ethibond. The adherence to silk was statistically lower than all of the high-tensile strength sutures.
CONCLUSIONS: Among high--tensile strength sutures, Orthocord has significantly less bacterial adherence than MaxBraid and FiberWire. Although infections in arthroscopic shoulder surgery are rare, the physical properties of surgical implants should be known by surgeons. In addition, bacterial adherence may contribute to suture selection in a patient prone to infection or to the use of suture in other body areas at greater risk for contamination. CLINICAL RELEVANCE: Bacterial adherence to high--tensile strength sutures may be a useful factor in implant selection in a patient with predisposition for contamination or infection. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21624678     DOI: 10.1016/j.arthro.2011.02.003

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  6 in total

1.  CORR Insights®: Does Suture Type Influence Bacterial Retention and Biofilm Formation After Irrigation in a Mouse Model?

Authors:  Daniel J Stinner
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

2.  Bacteria adhere less to barbed monofilament than braided sutures in a contaminated wound model.

Authors:  John R Fowler; Tiffany A Perkins; Bettina A Buttaro; Allan L Truant
Journal:  Clin Orthop Relat Res       Date:  2012-09-22       Impact factor: 4.176

3.  Does Suture Type Influence Bacterial Retention and Biofilm Formation After Irrigation in a Mouse Model?

Authors:  David C Markel; Christopher Bergum; Bin Wu; Therese Bou-Akl; Weiping Ren
Journal:  Clin Orthop Relat Res       Date:  2019-01       Impact factor: 4.176

4.  From Bench to Bedside: Semper Gumby-Like Living Tissue, Let's Stay Flexible.

Authors:  Benjamin K Potter
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

5.  The single-suture technique for anterior cruciate ligament graft preparation provides similar stability as a three-suture technique: a biomechanical in vitro study in a porcine model.

Authors:  Jan Theopold; Stefan Schleifenbaum; Alexander Georgi; Michael Schmidt; Ralf Henkelmann; Georg Osterhoff; Pierre Hepp
Journal:  Arch Orthop Trauma Surg       Date:  2020-01-24       Impact factor: 3.067

6.  FiberWire vs FiberTape: Comparison of Bacterial Adherence in a Murine Air Pouch Wound Model.

Authors:  Allison M Blumenthal; Therese Bou-Akl; Mario D Rossi; Bin Wu; Wei-Ping Ren; David C Markel
Journal:  Orthop J Sports Med       Date:  2020-12-15